Safety Instructions - RAMSET T4MAG Manual Del Propietario Y De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DANGER
PREPARATION FOR FASTENING
Acceptable Base Materials
The gas powered T4 tools are suitable
for use in the following
base materials only:
• Poured Concrete
• Structural Steel
• Concrete Block and Horizontal
Joints in Brick or Masonry Walls
Never attempt to fasten into any other
type of material. Fastening into other
materials can cause blindness or other
serious injury.
Never attempt to fasten into very hard or
brittle materials such as cast iron, tile,
glass, or rock of any type. These materials
can shatter, causing the fastener and/or base
material fragments to fly free and cause
serious injury to the tool operator and others.
Never fasten into any base material that
does not pass the Center Punch test.
Failure to assure the suitability of the base
material can result in serious injury to the
eyes or other body parts.
Center Punch Test
ALWAYS WEAR APPROVED EYE
PROTECTION WHEN PERFORMING THIS
TEST.
1. Always check the material being
fastened into for hardness before
attempting any fastening operation.
2. Using a fastener as a center punch,
strike the fastener against the work
surface using an average hammer
blow and check the results.
DANGER

SAFETY INSTRUCTIONS

Solid Concrete and
Precast Concrete
Solid or Hollow
Block
only in Brick Walls
Center Punch Test Results
1. If the fastener point is flattened,
the material is too hard for a
powder actuated fastening.
2. If the fastener penetrates the material
easily, the material is too soft.
3. If the material cracks or shatters,
the material is too brittle.
4. If the fastener makes a small
indentation into the material, the
material is suitable for fastening.
SAFETY INSTRUCTIONS
Structural Steel
Horizontal Joints
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T4ssT4 i-f

Tabla de contenido