WARNINGS
This manual is designed to assist qualified installation personnel only. It contains no information that
may be of interest to final users. This manual is attached to the D749MA-R control unit, therefore it may
not be used for different products!
Important warnings:
Disconnect the mains power supply to the board before accessing it.
The D749MA-R control unit is suitable for the control of a direct-current electromechanical gearmotor for
automating gates and doors of all kinds.
Any other use is considered improper and is consequently forbidden by current laws.
Please note that the automation system you are going to install is classifi ed as "machine construction"
and therefore is included in the application of European directive 2006/42/EC (Machinery Directive).
This directive includes the following prescriptions:
-
Only trained and qualified personnel should install the equipment;
-
the installer must first make a "risk analysis" of the machine;
-
the equipment must be installed in a correct and workmanlike manner in compliance with all the
standards concerned;
-
after installation, the machine owner must be given the "declaration of conformity".
This product may only be installed and serviced by qualified personnel in compliance with current, laws,
regulations and directives.
When designing its products, TAU observes all applicable standards (please see the attached declaration
of conformity) but it is of paramount importance that installers strictly observe the same standards when
installing the system.
Unqualified personnel or those who are unaware of the standards applicable to the "automatic gates
and doors" category may not install systems under any circumstances.
Whoever ignores such standards shall be held responsible for any damage caused by the system!
Do not install the unit before you have read all the instructions.
INSTALLATION
Before proceeding, make sure the mechanical components work correctly. Also check that the gear
motor assembly has been installed according to the instructions. Then make sure that the power con-
sumption of the gear motor is not greater than 3A (otherwise the control panel may not work properly).
THE EQUIPMENT MUST BE INSTALLED "EXPERTLY" BY QUALIFIED PERSONNEL AS REQUIRED BY LAW.
Note: it is compulsory to earth the system and to observe the safety regulations that are in force in
each country.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE PROPER WORKING ORDER
OF THE EQUIPMENT AND CREATE HAZARDOUS SITUATIONS FOR PEOPLE. FOR THIS REASON THE "MANUFAC-
TURER" DECLINES ALL RESPONSIBILITY FOR ANY MALFUNCTIONING AND DAMAGES THUS RESULTING.
1. CONTROL PANEL FOR ONE-TWO 24V MOTORS WITH ENCODER
•
LOGICS WITH MICROPROCESSOR
•
STATUS OF INPUTS SIGNALLED BY LEDs
•
INCORPORATED FLASHING CIRCUIT
•
ENCODER SENSOR FOR SELF-LEARNING OF TRAVEL
•
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
•
BATTERY CHARGER BOARD (INTEGRATED)
•
BATTERY CONNECTOR
•
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
•
POSSIBILITY OF ENERGY SAVING OPERATION
•
COMPATIBILITY WITH OUR APPS: TAUOPEN AND TAUAPP
ATTENTION:
-
For correct operation, you have to use the TAU cable cod. M-030000CC50 for connecting the
motors to the control unit or cables with a section of not less than 2.5 mm
15