Technical Data; Electrical Data - Kaco blueplanet 3.0 TL3 Instrucciones De Operación

Ocultar thumbs Ver también para blueplanet 3.0 TL3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 88
4

Technical data

4.1

Electrical data

DC Input levels
Recommended generator power
range
MPPrange@Pnom
Working range
Rated voltage
Starting voltage
Open circuit voltage
2
Max. input current
Number of strings
Number of MPP controls
Max. short-circuit current (ISC
max.)
Input source feedback current
Polarity safeguard
String fuse
DC overvoltage protection
AC Output levels
Nominal power
Rated voltage
Voltage range: continuous opera-
tion
2
The "Max. input current" is the maximal theoretical value during operation at full power and minimal MPP voltage.
The inverter will clip to the maximum AC power output.
The "Max. short-circuit current (ISCmax.)" defines together with open circuit voltage (Uocmax) the characteristic of
the connected PV generator. This is the relevant value for string sizing and is the absolute maximal limit for inverter
protection. The connected PV-Generator must be designed, that the max short circuit current is below or equal to
ISCmax of the inverter under all foreseeable conditions. In no condition the design may result in a greater short cir-
cuit current than ISCmax of the inverter.Designing the PV generator [See section 7.5.4} Page 22].
Page 10
KACO
KACO
KACO
blue-
blue-
blue-
planet
planet
planet
3.0 TL3
4.0 TL3
5.0 TL3
M2 WM
M2 WM
M2 WM
OD IIG0
OD IIG0
OD IIG0
3.6 kW
4.8 kW
6 kW
240-800
200-800 V
V
KACO
KACO
KACO
blue-
blue-
blue-
planet
planet
planet
3.0 TL3
4.0 TL3
5.0 TL3
M2 WM
M2 WM
M2 WM
OD IIG0
OD IIG0
OD IIG0
3 kVA
4 kVA
5 kVA
KACO blueplanet 3.0 TL3 KACO blueplanet 4.0 TL3 KACO blueplanet 5.0 TL3 KACO blueplanet 6.5 TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6 TL3 KACO blueplanet 9.0 TL3 KACO blueplanet 10.0 TL3
KACO
KACO
KACO
blue-
blue-
blue-
planet
planet
planet
6.5 TL3
7.5 TL3
8.6 TL3
M2 WM
M2 WM
M2 WM
OD IIG0
OD IIG0
OD IIG0 -
3TL301
Input levels (DC)
7.8 kW
9 kW
10.3 kW
310-800
350-800
403-800
V
V
V
200 V - 950 V
653 V
250 V
1,000 V
2 x 11 A
1
2
2 x 16 A
0 A
yes
no
Built-in
KACO
KACO
KACO
blue-
blue-
blue-
planet
planet
planet
6.5 TL3
7.5 TL3
8.6 TL3
M2 WM
M2 WM
M2 WM
OD IIG0
OD IIG0
OD IIG0 -
3TL301
Output levels (AC)
6.5 kVA
7.5 kVA
8.6 kVA
220 / 380 V [3/N/PE];
230 / 400 V [3/N/PE];
240 / 415 V [3/N/PE]
305 V - 480 V [Ph-Ph]
KACO
KACO
blue-
blue-
planet
planet
9.0 TL3
10.0 TL3
M2 WM
M2 WM
OD IIG0
OD IIG0 -
3TL301
10.8 kW
12 kW
420 - 800
470-800
V
V
KACO
KACO
blue-
blue-
planet
planet
9.0 TL3
10.0 TL3
M2 WM
M2 WM
OD IIG0
OD IIG0 -
3TL301
9 kVA
10 kVA

Publicidad

Tabla de contenido
loading

Tabla de contenido