(2) REMOVE ALL NAILS FROM NAILER.
DO NOT push or rest Push Lever against any surface.
DO NOT FORCE OR USE TOOLS TO OPERATE
SWITCH.
Select SINGLE SEQUENTIAL ACTUATION MODE
according to the following steps.
1 Open the change stopper by pushing the bottom of
trigger.
2 Grasp the change rod between two fi ngers (one on
each side of the trigger) and slide it down (Single
Sequential Actuation Mode.)
3 Confi rm that the change stopper has completely
returned to original position inside the trigger.
(SINGLE SEQUENTIAL ACTUATION MECHANISM).
Grasp The
Change Rod
2
1
Push The Change stopper
(3) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
□ THE NAILER MUST NOT LEAK AIR.
(4) Remove the fi nger from the trigger and press the
(5) Separate the push lever from the wood.
3
Position of
Change Rod
(6) First pull the Trigger.
(7) Without touching the Trigger, depress the Push Lever
).
2
(8) Disconnect the air hose.
push lever against the wood.
□ THE NAILER MUST NOT OPERATE.
Depress
Push Lever
Next, point the nailer downward, pull the trigger and
then wait in that position for 5 seconds or longer.
□ THE NAILER MUST NOT OPERATE.
Pull Trigger
Next, depress the Push Lever against the wood.
□ THE NAILER MUST NOT OPERATE.
against the wood.
Next, pull the Trigger.
□ THE NAILER MUST OPERATE.
If the lock pin is left, skip (8) through (10) and
proceed from (11).
→ If the lock pin is attached, the unit can be
operated in SINGLE SEQUENTIAL ACTUATION
MECHANISM.
REMOVE ALL NAILS FROM NAILER.
Remove the hook if it is attached.
→ When the hook is attached, do not operate with
CONTACT ACTUATION MECHANISM.
English
Do not pull Trigger
13

Publicidad

Tabla de contenido
loading

Tabla de contenido