Franklin Electric Little Giant PES Serie Hoja De Instrucciones
Franklin Electric Little Giant PES Serie Hoja De Instrucciones

Franklin Electric Little Giant PES Serie Hoja De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Franklin Electric Co., Inc
Oklahoma City, OK 73157-2010
www.lg-outdoor.com
customerservice@lgpc.com
INTRODUCTION
EN
This instruction sheet will provide you with information required
to safely own and operate Little Giant PES Series pump. The
pump you have purchased is a submersible epoxy encapsulated
pump, with outer case constructed of durable polyester and
ABS plastic. The case is filled with a special heat transfer epoxy.
The instruction sheet primarily covers the standard models of
each pump series. The form is applicable to other models in the
series not listed by catalog number in the replacement parts list
section of the instruction sheet. If the catalog number of your
pump is not listed in the replacement parts list section, then
caution should be exercised when ordering replacement parts.
Always give the catalog number of your pump when ordering
replacement parts.
The Little Giant unit you have purchased is of the highest
quality workmanship and material It has been engineered to
give you long and trouble-free service. The Little Giant pumps
are carefully packaged, inspected and tested to insured safe
operation and delivery. When you receive your pump, examine
it carefully to determine that there are no broken or damaged
parts that may have occurred during shipment. If damage
has occurred, make notation and notify the firm that you
purchased the pump from. They will assist you in replacement
or repair, if required.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING
TO INSTALL, OPERATE OR SERVICE THE LITTLE GIANT
PUMP. KNOW THE PUMP APPLICATION, LIMITATIONS, AND
POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS
BY OBSERVING ALL SAFETY INFORMATION. FAILURE
TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN
INSTRUCTIONS FOR FUTURE REFERENCE.
SAFETY GUIDELINES
1. Make certain that the unit is disconnected from the power source
before attempting to service or remove any component.
2. Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not use in explosive
atmospheres. Pump should only be used with liquids
compatible with pump component materials.
3. Do not handle pump with wet hands or when standing on a wet
or damp surface or in water.
4. This pump is supplied with a grounding conductor and/or
grounding type attachment plug. To reduce the risk of electric
shock. be certain that it is connected to a properly grounded
grounding type receptacle.
5. In any installation where property damage and/or personal
injury might result from an inoperative or leaking pump due to
power outages, discharge line blockage, or any other reason,
a backup system(s) and/or alarm should be used.
6. Support pump and piping when assembling and when installed.
Failure to do so may cause piping to break, pump to fall, motor
bearing failures, etc.
PES-A-PW
PES-100-PW
7. If pump is an oil-filled pump, the motor housing is filled with
a dielectric lubricant at the factory for optimum motor heat
transfer and lifetime lubrication of the bearings. Use of any
other lubricant could cause damage and void the warranty.
This lubricant is non-toxic; however, if it escapes the motor
housing, it should be removed from the surface quickly by
placing newspapers or other absorbent material on the water
surface to soak it up, so aquatic life is undisturbed.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not
connect to voltage other than that shown.
2. If pump is supplied with a 3-prong electrical plug, the third
prong is to ground the pump to prevent possible electrical
shock hazard. DO NOT REMOVE the third prong from the
plug. A separate branch circuit is recommended. Do not
use an extension cord. Do not cut plug from the cord. If
the plug is cut or the cord is shortened, then this action will
void the warranty.
3. If the cord is equipped with stripped lead wires, such as on
230v models, be sure that the lead wires are connected to a
power source correctly. The (green/yellow) wire is the ground.
The (blue or white) and the (brown or black) are live.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR
PROPER ASSEMBLY AND DISASSEMBLY OF YOUR LITTLE
GIANT PUMP.
OPERATION
1. The PES model pumps must be operated in clean fresh water
with the volute intake below the liquid level.
2. The pumps can be placed in any position. There are four suction
cup feet provided with the pump. To install the suction cups, wet
the ends and press them into the four holes on the bottom of the
intake housing.
3. The weight of the pumps must be supported adequately. DO
NOT support the pumps by the discharge connection alone.
4. The discharge is designed for use with 1/2" ID flexible tubing.
An adaptor that fits inside of the discharge is included to allow
the use of 3/8" ID flexible tubing.
5. The flow rate on the PES Series pump can be adjusted by
rotating the flow adjuster located on the front of the pump.
Rotate the adjuster counterclockwise to increase flow and
clockwise to decrease flow. If flow rate needs to be reduced
even further, then place a valve on the discharge side of the
pump or if flexible tubing is used, a clamp can be used on
the tubing.
6. If the unit is going to be idle for a period of time, follow the
cleaning instructions outlined in the next section. Do not let
the unit freeze in the wintertime. This may cause cracking or
distortion that may destroy the unit.
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little Giant PES Serie

  • Página 1 PES-A-PW transfer and lifetime lubrication of the bearings. Use of any other lubricant could cause damage and void the warranty. Franklin Electric Co., Inc PES-100-PW This lubricant is non-toxic; however, if it escapes the motor Oklahoma City, OK 73157-2010 housing, it should be removed from the surface quickly by www.lg-outdoor.com...
  • Página 2: Directives De Securite

    SERVICE INSTRUCTIONS DIRECTIVES DE SECURITE MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM 1. Veiller à débrancher l’appareil de sa source d’alimentation THE POWER SOURCE BEFORE ATTEMPTING TO SERVICE OR électrique avant l’entretien ou la dépose d’une ou de plusieurs REMOVE ANY COMPONENT! piéces.
  • Página 3: Directives D'ENtretien

    FONCTIONNEMENT INTRODUCCIÓN 1. La pompe doit être utilisée dans de l’eau propre, et l’entrée de la volute doit être sous le niveau du liquide. Esta hoja de instrucciones le proporcionará la información 2. Elles peuvent être installées dans n’importe quelle position. requerida para que pueda ser propietario de y poner en Quatre pattes à...
  • Página 4: Conexiones Electricas

    5. En cualquier instalación en la cual puedan producirse daños 6. Si la unidad se mantiene sin funcionar por un período de materiales/o lesiones personales causados por bombas que tiempo largo, siga las instrucciones de limpieza descritas en la no funcionan o tienen escapes, debido a interrupciones del próxima sección.
  • Página 5 Flow Control Contrôle du Debit Control de Flujo PES-A-PW PES-100-PW ITEM NO. PART NO. DESCRIPTION 115V/ 230V/ 115V/ 230V/ ARTICLE PARTIE NO. DESCRIPTION 60 HZ. 60 HZ. 60 HZ. 60 HZ. ARICULO PARTE NO. DESCRIPCION 119554 Intake Housing 119556 Volute Plate 599088 IRA-A 119621...
  • Página 6: Garantie Limitée

    LE RECOURS EXCLUSIF DE L'ACHETEUR POUR UN PRODUIT DÉFECTUEUX. use, improper maintenance or repair, damage or casualty, or to an excess Franklin Electric Company, Inc et ses filiales (ci-après « la Société ») garantit of the recommended maximums as set forth in the product instructions.
  • Página 7: Garantia Limitada

    DEFECTUOSO. autorisée de produits ne provenant pas de la Société à d'autres produits de Franklin Electric Company, Inc y sus subsidiarias (en adelante “la Compañía”) la Société, et la modification non autorisée des produits de la Société. garantizan que los productos que están acompañados por esta garantía se 6.
  • Página 8 11. Productos en los cuales la bomba fue utilizada para bombear o circular otra cosa Esta Garantía Limitada le otorga derechos legales específicos. También pueden aparte de agua potable a temperatura ambiente. existir otros derechos que pueden variar según las leyes y regulaciones aplicables.

Este manual también es adecuado para:

Little giant pes-a-pwLittle giant pes-100-pw

Tabla de contenido