With Heated Humidification

CAUTION–The height of the SleepCube must be lower than the mask when using a humidifier to prevent water from
getting into mask.
1.
If your system includes a humidifier, please follow steps in Figures 1-7.
a.
Locate the heater power connector on the bottom of the device. Remove the connector cover and insert it into
the storage opening in the bottom of the humidifier cradle.
b.
Locate the air supply port at the bottom of the device. Remove the port plug and insert it into the air supply
port in the back of the device.
c.
Place device onto humidifier cradle and click into place.
d.
F ill clean chamber to fill line with distilled water and insert into cradle. NOTE-Always use distilled water to
avoid mineral buildup inside the chamber. Do not overfill.

KEYpaD aND DiSpLaY

basic Cpap Controls
Name
Symbol
ON/OFF
HEATER
DELAY
NOTE– The left and right arrow keys on the control panel provide access to menus for specific settings. Ask your
homecare provider for more information.

OpERatiON

1.
Fully insert the power cord into the back of the device. Plug the other end of the power cord into the AC wall outlet.
2.
Attach air supply tubing to air supply port in the back of the device.
3.
Prepare the mask (supplied by your equipment provider) by referring to the mask's instruction guide.
4.
Connect the air supply tubing to the mask.
NOTE–The air supply tubing supplied with the device is specially designed to prevent kinking and allow you to receive
optimal airflow. Use only the 22 mm diameter, smooth-bore, kink-resistant tubing supplied with this device or an air supply
tubing recommended by your equipment provider.

Start-up

Put on your mask and press the ON/OFF button on the keypad OR put on your CPAP mask and take a few breaths to turn
on airflow automatically. The pressure in your mask will rise to the set pressure in about 10 seconds.
NOTE–If the device does not automatically start after taking 2-3 breaths, this feature may have been disabled. If Auto ON/
OFF is disabled, you must manually press the ON/OFF button to start and stop the device.
The keypad display shows the actual mask pressure while the device is in use. Because this is the actual pressure, the
device pressure reading may vary slightly as you breathe.
If your DeVilbiss SleepCube system includes a humidifier, its heater controls and status are displayed.
NOTE– If the display on your device is not similar to those listed above, refer to the section titled "Patient Messages" on
page EN-8.
Controlling the Humidity (optional)
The heater setting can be adjusted within a range of 1 to 10. The optimum temperature setting is dependent on the
ambient temperature and humidity of your room. If your room temperature is low and/or the relative humidity is high, then a
lower temperature setting may be necessary to prevent excess condensation in the air supply tubing. If the room
temperature is high and/or the relative humidity is low, then a higher temperature setting may be necessary for optimum
comfort.
The heater setting of 1 results in a heater plate temperature of approximately 84˚F (29˚C). The heater setting of 10 results
in a heater plate temperature of approximately 149˚F (65˚C).
EN - 6
Function
The ON/OFF button starts and stops the flow of air from the device.
If your SleepCube has a heater/ humidifier attached, these buttons adjust the heater setting.
Increase the setting for more humidity and decrease the setting for less humidity.
The Delay button activates the comfort delay feature and only functions if this feature has been
enabled. To understand how to set the parameters of this feature, please refer to the Using the
Comfort Delay Feature found on page EN - 7.