Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

cHecK water inlet strainer
CAUTION
risK of unit damage!
do not overtigHten tHe
unloader. breaKage could
result in immediate loss of
water pressure and costly
repairs.
2 
installation & preparation
water supply:
.  Select a water supply hose which is a quality grade of garden hose measuring 
at least 3/4" ID and no longer than 50 feet.
2  Check the water inlet strainer to ensure it is clean and free of any obstructions.   
Periodic cleaning of the water strainer will help prevent pump problems.  As 
a strainer becomes obstructed, it restricts proper flow of water to the pump.
This can result in cavitations which will cause premature failure of pump 
packings.  
a.  Using a screw driver, remove the screen from the water inlet.
b.  Clean or replace with Mi-T-M
 3.  Connect the hoses.
a.  Connect  one  end  of  the  water  supply  hose  to  the  water  inlet  of  the 
unit.  
b.  Connect the other end of the hose to your pressurized water supply.
NOTE: 
Do not use a non-pressurized water supply (i.e. from a pond or well)
with this unit.
c.  Connect the high pressure discharge hose to the water outlet of the 
unit. 
d.  Securely connect the other end of the hose to the gun assembly.  (A 
wrench may be required on some models.)
e.  Connect the wand assembly to the gun/hose assembly.
4.  Follow the incoming water requirements listed below:
a.  Water pressure must be a minimum of 25 pounds per square inch (PSI) 
and a  maximum  of 25 PSI.  (A typical outdoor  faucet  will generally 
supply this PSI if turned completely "ON".) 
b.  Incoming  GPM  must  be    approximately  one  gallon  more  than  the 
outgoing  GPM  stated  on  the  pressure  washer  nameplate.    (You  can 
check GPM by timing how long it takes to fill a 5 gallon container.)
c.  Incoming water temperature must not exceed 25°F.  Excessive pump 
damage may result if the water temperature exceeds this acceptable 
level.
5.  Never allow the unit to operate without the incoming water line attached and 
the water supply completely turned on.

unloader:

tHe unloader will eitHer be adjustable or factory preset
depending on tHe model you purcHased.
adjustable:
The  unloader  valve  on  your  machine  is  equipped  with  an  adjustment    knob 
to  adjust  the  pressure.    Should  less  pressure  be  required,  simply  turn  the 
adjustment knob counterclockwise.  To set back to maximum, turn adjustment 
knob completely clockwise.  DO NOT OVERTIGHTEN!
factory preset:
The  unloader  valve  on  your  machine  is  factory  preset  and  should  only  be 
adjusted by a trained Mi-T-M Representative. DO NOT adjust the pressure on 
your own!
Adjustable
 #9-000 if necessary.
®
Factory Preset
WP-Cold Water Direct Driven Operator's Manual