Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

storage & maintenance

winterizing:

For storage and transportation purposes in subfreezing ambient temperatures, 
it will be necessary to winterize this unit.  This unit must be protected to the 
lowest incurred temperature for the following reasons:
1. If any part of the pumping system becomes frozen; excessive pressure
may build up in the unit which could cause the unit to burst resulting in 
possible serious injury to the operator or bystanders. 
2.  The pumping system in this unit may be permanently damaged if frozen. 
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall below 
32°F, you can protect your unit by following the procedure outlined below.
.  Gather the following items:
a.  Two 5 gallon containers.
b.  One gallon of antifreeze.  (Work Pro
safe antifreeze.)
c.  Water supply.
d.  Three  foot  hose,  /2-3/4  I.D.  with  a  3/4  inch  male  garden  hose 
fitting.
2.  Procedure:
a.  To  start  winterizing,  unit  must  be  run  and  primed  according  to  the 
"Start-up Procedures" listed on page 4.
b.  After running and priming, shut off the unit and water supply.
c.  Relieve system pressure by pointing the trigger gun in a safe direction 
and squeezing the trigger until water flow ceases to exit the nozzle.
d.  Lock the trigger gun in an OFF position and remove the nozzle.
e.  In one 5 gallon container, mix the antifreeze and water according to 
manufacturer's  recommendations  for  the  temperature  to  which  you 
are winterizing. 
NOTE: Proper winterizing is based on the recommended manufacturer's
instructions listed on the "Protection Chart" shown on the back label
of most antifreeze containers.
f.  Remove  the  water  supply  hose  from  the  unit  and  attach  the  3  foot 
hose securely to the inlet connection.  Submerge the other end into 
the antifreeze solution.
g.  Shut off the detergent injector if applicable. 
h.  Point the wand into the empty container and start the unit.
i.  Trigger the gun until the antifreeze begins  to exit the wand.  Release 
the trigger for 3 seconds, then trigger the gun for 3 seconds.  Continue 
cycling the gun several times until all the antifreeze mixture is siphoned 
from the container.
j.  Stop the unit.
k.  Detach the 3 foot hose from the unit and drain any excess antifreeze 
back into the 5 gallon container.
l.  Disconnect the hose/gun/wand assembly from the unit and drain any 
excess antifreeze back into the 5 gallon container.
m.  Store the hose, gun and wand with the unit in a safe, non-freezing 
area.
n.  Store antifreeze solution for next use or dispose of according to state 
EPA laws.
3.  Optional Procedure:
a.  Shut the unit and water supply off.
b.  Relieve system pressure by pointing the trigger gun in a safe direction 
and squeezing the trigger until water flow ceases to exit the nozzle.
c.  Disconnect and drain the hose, gun and wand.
d.  Start the unit and allow it to run until all the water exits the unit.  Once 
the water has stopped flowing from the unit, turn the unit off.
NOTE: When using this procedure, caution should be used as ice chips can
form from drops of water which could cause the unit to burst if starting
before completely thawed.
 WP-Cold Water Direct Driven Operator's Manual 
 recommends an environmentally 
®
WARNING
risK of unit bursting!
do not store/operate unit
in a freezing environment!
32˚F
0˚C
7