STUDER Innotec SA
Model
Inverter
Nominal battery voltage
Input voltage range
Continous power at 25ºC
Power 30 min. at 25ºC
Power 5 min.at 25ºC
Power 5 sec. at 25ºC
Maximum asymmetric load
Max. efficiency (%)
Cos φ max.
Detection of the load
Current of chort-circuit 2 sec. (exit)
Output voltage
Frequency
Distortion THD (resistive load)
Consumption Stand-by
Consumption „ON" no load
Overheat protection (±5ºC)
Short circuit protection
Reverse polarity protection by internal fuse
Deep discharge battery protection
Max. battery voltage
Acoustic alarm
General data
Weight
Dimensions hxwxl (mm)
Protection index IP
Certification ECE-R 10 (E24)
EC confirmity
Operating temperature
Relative humidity in operation
Ventilation forced
Acoustic level
Warranty
Approximate correction of Pnom
Recommended battery capacity
Length cables (Battery/left AC)
Options
Voltage max
Current max.
Solar regulator
Principle
Absorption voltage
Floating voltage
Remote control JT8 supplied with 5 m cable
AJ 1000-12
AJ 1300-24
12Vdc
24Vdc
10.5 – 16Vdc
21 – 32Vdc
(24Vdc max.)
(44Vdc max.)
800VA
1000VA
1000VA
1300VA
1200VA
2000VA
2200VA
2800VA
500VA
600VA
93%
0.1 – 1 up to 800VA
0.1 – 1 up to 1000VA
10Aac (20Aac*)
13Aac (26Aac*)
50Hz (60Hz*) ±0.05% (crystal controlled)
< 5% (at Pnom. & Uin nom.)
0.7W
1.2W
10W
Automatic disconnection with 2 restart attempts
125A
100A
Shut off at 0.87 x Unom, Automatic restart at Unom.
Shut off at >1.33 x Unom, Automatic restart at < Umax
Before low battery or overheating disconnection
8.5 kg
142x428x84
IP 30 conforms to DIN 40050
●
EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 60950-1
> 5 x Pnom/Unom (recommended value in Ah)
1.5m /1m
AJ 1000-12
AJ 1300-24
25Vdc
45Vdc
25Adc
14.4Vdc
28.8Vdc
13.6Vdc
27.2Vdc
●
V3.01
AJ2100-12
12Vdc
10.5 – 16Vdc
(20Vdc max.)
2000VA
2100VA
2450VA
5000VA
1000VA
94%
92%
0.1 – 1 up to 2000VA
Adjustable: 1 20W
26Aac (52Aac*)
Sine wave 230Vac (120Vac*) ±5%
0.7W
13W
16W
Shut down at 75ºC, Auto-restart at 70ºC
Not protected
19 kg
IP 20 conforms to DIN 40050
●
●
-20ºC up to +50ºC
95% without condensation
From 45ºC ±5ºC
< 45 dB (with ventilation)
5 years
-1.5%/ºC as from +25ºC
AJ2100-12
25Vdc
3 floating stages (I/U/UO)
14.4Vdc
13.6Vdc
●
●
AJ
AJ 2400-24
24Vdc
21 – 32Vdc
(40Vdc max)
2000VA
2400VA
2800VA
5200VA
1200VA
94%
0.1 – 1 up to 2000VA
30Aac (60Aac*)
< 3% (at Pnom. & Uin nom.)
1.2W
16W
150A
18 kg
273x399x117
●
1.7m / 1m
AJ 2400-24
45 Vdc
30Adc
28.8Vdc
27.2Vdc
●
14