RINSE INJECTOR AFTER EACH USE
Additive allowed to remain in injector can dry, foul or
damage the lower end at the next start-up. Place suction
tube into a 1 qt. (0.95 liters) or more container of fresh
filtered water. Flow fresh water through the injector by
operating until container is empty. This procedure is not
needed for continuous operation.
CLEAN SOLUTION CONTAINER
Keep covered to prevent dirt, flies and other debris from
entering the container. Rinse container thoroughly and
often. Do not mix chemicals together that might react
and cause a precipitate. Use FILTERED fluid when filling
container.
CLEAN SUCTION TUBE FILTER SCREEN
Inspect each time new solution is added. Clean filter
screen (#27) and suction tube (#25) as necessary by
rinsing in fresh water. Replace if necessary. Keep filter
screen off bottom of solution container to prevent dirt
and precipitate from clogging filter.
CLEAN INLET FILTER
Clean or replace inlet filter as required to increase the life
of the unit as well as reduce pressure loss.
BYPASS INJECTOR
When not in use place the injector in bypass mode by
using the three valve bypass.
STORAGE
For extended storage, rinse injector (see "Rinse Injector
After Each Use") and place underwater in a container.
Apply monthly, <0.1 oz. (29 ml) of chlorine bleach to
avoid algae growth. KEEP FROM FREEZING.
English: 10
Remote Injecting
Remote Injector Kit
Is recommended for the following:
Single Injector:
Fig. 6
To prevent mineral buildup within the body of the unit.
Use when injecting chemicals that cause minerals to
Remote Injector
precipitate from fluid (see Fig. 6)
Kit shown on a
single injector.
NOTE: when mixing more than one chemical, always
refer to your chemical manufacturer information guide
for proper application. Contact your local distributor or
Dosmatic customer service for information or to order.
Maintenance
Reference numbers refer to Page 13 - 17
1. Clean seal areas
(#51 & 13).
2. Check #17 O-ring,
#68 Cylinder, clean
and/or replace as
necessary.
1. Clean seal areas
(#14 & 13).
2. Check #17 O-ring,
#7 Cylinder, clean
and/or replace as
necessary.
(not included)
Perform these maintenance
procedures to extend the life of your unit.
Refer to page 14
SuperDos 15 (0.3%) Model
Every 3 - 6
Every 6 - 12
Months
months
1. Replace #17 O-ring
#51 Shaft Assembly.
2. Clean and/or replace
#13 Check Poppet, #11
Suction Tube Fitting, #68
inner cylinder.
Refer to page 15, 16 & 17
SuperDos 15 (2.5% & 2.5% WSP), (5%) Models
Every 3 - 6
Every 6 - 12
Months
months
1. Replace #17 O-ring
and #44 Dosage Piston/
gasket (WSP model).
2. #13 Check Poppet ,
#11 Suction Tube Fitting.
Kit Part Numbers
012705
Replace as
necessary
1. #68 Cylinder
2. #51 Shaft
Assembly Dosage
Piston
Replace as
necessary
1. #7 Cylinder
2. #14 O-ring