OPERATING INSTRUCTIONS
3. Pump Drain
In situations where the drain hose cannot reach a
fl oor drain or if the drain hose needs to reach a
receptacle that is above the level of the appliance,
water can be drained from the appliance using the
pump.
1. Remove the cap on the pump drain port on the
back of the appliance.
2. Connect the provided drain hose to the drain
port.
3. Ensure that there are no bends in the drain hose.
4. Press the pump button to initiate the pump drain.
5. The maximum length of the pump drain hose is
5 m (16 feet).
INTERNAL PUMP ARM
Inside the appliance there is a pump arm that will
draw water out of the bucket and then drain it out
through the drain hose. When replacing the bucket
in the appliance after emptying it, ensure that the
pump arm has not fallen down or the bucket will not
go back into the appliance.
If the pump arm has fallen down, gently push it up
toward the top of the unit until it clicks into place.
Note: The pump will only become active once the
bucket is full of water.
As the dehumidifi er removes water from the air, the
water will fi rst fi ll the bucket. When the bucket is full,
the pump arm will drop into the bucket and remove
as much water as it can reach. The water will drain
through the attached drain hose.
The appliance will continue to function, removing
more water from the air and fi lling the bucket
again.
6