Pre-Operation (continued)
PLACEMENT OF THE AIR COMPRESSOR
WARNING: If any parts are damaged or missing do
not operate this product until the parts are replaced.
Failure to heed this warning could result in serious
personal injury.
CAUTION: Do not use in an environment that is dusty
or otherwise contaminated. Using the air compressor in
this type of environment may cause damage to the unit.
NOTE: Long lengths of electrical wiring could cause power
loss to the motor.
□
Place the air compressor in a clean, dry, and well
ventilated area.
□
The air compressor must be positioned at least
18 in. (0.5 m) away from the wall or other
obstructions that will interfere with the flow of air.
□
Locate the air compressor as close to the main
power supply as possible to avoid using long
lengths of electrical wiring.
□
The air filter must be kept clear of obstructions
which could reduce air flow to the air compressor.
INSTALLING THE AIR INTAKE FILTER
CAUTION: Do not attempt to start the air compressor
without first installing air intake filter and the fill cap/
breather. The pump is shipped with oil from the factory,
but pump can build internal pressure and blow off cap,
if breather is not installed. Only use non-detergent
oils when refilling, because the multi-viscosity motor
oils leave carbon deposits on pump components, thus
reducing the performance and compressor life.
□
Remove the plastic plug (1) from the compressor
head (2). Remove the air intake filter (3) from the
poly bag and thread it into the compressor head (2),
as shown.
10
18 in.
(0.5 m)
1
2
3