Be sure to check these items first:
Is there a power outage in the area?
Is the household fuse blown or the circuit breaker
tripped?
Is the appliance properly connected to the electrical
supply?
Many problems can be resolved without the need for a
service call. See the following list as a reference of
possible solutions of simple problems.
Symptom
Appliance is not cooling.
The compressor is constantly
running or running too much.
Products and beverages in the unit
are too cold.
Possible Cause
Appliance has been switched off.
Appliance opened frequently.
The ventilation openings have been
covered.
A large amount of product, or warm
product was placed into the appliance.
Excessively warm environment.
Leveling legs are not extended.
Door gasket is not sealing.
Temperature has been set too low.
Product placed too close to ventilation
holes.
Potential Remedy
Check display to make sure the unit is
not switched off. If display reads "OFF",
simultaneously press and hold LOCK
and WARMER to return to operating
mode.
Do not open the appliance
unnecessarily.
Remove obstacles at the ventilation
openings located at the base of the unit
and in the refrigerator interiors.
The compressor will run more than
normal until the product cools. The
more that is added, the longer the motor
will run.
Avoid placing the unit in direct sunlight,
or near a heat source. If the appliance is
in an unusually warm environment, the
compressor will run more.
Extend the leg height to improve air
circulation. This will reduce the amount
of time the compressor needs to run.
Inspect the condition of the gasket. If
damaged, cold air can escape the
cabinet and cause the compressor to
run more than normal.
Increase the temperature. See "Setting
the temperature".
Rearrange the bottles, so that nothing
obstructs the interior ventilation holes.