1.- BUILDING-IN.
The water heater shall be built-in as close as possible to the outlets in order to reduce the heat loses.
The building place must be chosen considering the maximum reduction of 90º elbows in water
connections and, at the same time, make easy the substitution of the heating element.
2.- APPLIANCE WALL HANG
Due to its particular design, the APARICI electrical water heaters could be installed in three positions as
you could see at fig-2.1, 2.2 and 2.3:
1. Vertical. At this position cold water inlet pipe (F) is on the right side and hot water outlet pipe (C) on the
left side. The hydraulic safety valve supplied with the appliance must be installed at the inlet cold water
pipe (F).
MODEL
SIE030N
SIE050N
WATER
G1/2'
Ø380
A
548
B
380
C
210
D
E
F
fig.-1 – Model APARICI SIExxxN/SIE075S
DIMENSIONS
SIE075S
SIE075N
G1/2'
G1/2'
G1/2'
Ø380
Ø380
Ø450
748
1042
813
380
380
470
420
420
450
265
210 - 350
270
395
Fig. 2.1
10
SIE100N
SIE120N
G1/2'
G1/2'
Ø450
Ø450
963
1123
470
470
610
610
355
210 - 440
340
465