The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
OPERATION
The device has two operating modes. It can be operated via IR remote control or it can be run in DMX-
controlled mode via a DMX controller.
After you connected the color changer to the mains, the device starts running.
Operation via IR Remote Control
DMX-controlled operation
You can control the spots individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. The individual channels and their features are listed under DMX-protocol.
The starting address can be defined via the remote control and is the first channel from which the device will
respond to the controller.
Example for setting the DMX starting address 245:
Step 1: Press button S on the remote control. The red LEDs light, indicating you can start setting the
address.
Step 2: Press button 2. The green LEDs light. The setting of the 100
Step 3: Press button 4. The blue LEDs light. The setting of the 10
Step 4: Press button 5. All LEDs light. The setting of the 1
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
FUNCTION
Manual color adjustment
via the brightness of the RGB LEDs
Automatic change
speed for change of color adjustable
Sound-controlled color change*
*only available for indoor models
Programs
7 static colors; color change and color
fade with adjustable speed
Flash
speed of flash adjustable
Black Out
turns
LEDs
on and off
DMX starting address
DMX controlled mode
Slave mode
17/35