Téléchargé sur www.confort-electrique.fr
11) RECEIVER CONFIGURATION
The on-board receiver combines characteristics of utmost safety in
copying variable code (rolling code) coding with the convenience of
carrying out transmitter "cloning" operations thanks to an exclusive
system.
Cloning a transmitter means creating a transmitter which can be
automatically included within the list of the transmitters memorised
in the receiver, either as an addition or as a replacement of a par-
ticular transmitter.
Cloning by replacement is used to create a new transmitter which
takes the place of the one previously memorised in the receiver; in
this way a specific transmitter can be removed from the memory and
will no longer be usable.
Therefore it will be possible to remotely program a large number
of additional transmitters or, for example, replacement transmitters
for those which have been lost, without making changes directly to
the receiver.
When coding safety is not a decisive factor, the on-board receiver
allows you to carry out fixed-code additional cloning which, although
abandoning the variable code, provides a high number of coding
combinations, therefore keeping it possible to "copy" any transmitter
which has already been programmed .
12) RADIO-TRANSMITTER CLONING (Fig.7)
Rolling-code cloning / Fixed-code cloning
Make reference to the
universal palmtop programmer
and the CLONIX Programming Guide.
12.1) ADVANCED PROGRAMMING: COLLECTIVE RECEIVERS
Make reference to the
universal palmtop programmer
and the CLONIX Programming Guide.
13) ACCESSORIES
SPL (fig.4).
Pre-heating optional board. Recommended for temperatures below
-10°C. (In the case of hydraulic motors).
ME (fig.5).
Optional board used to connect a 12V~ electric lock.
Note: the ME optional board is not operated by the START control
of the integrated radio board. For the correct functioning of the ME
optional board use one of the following configurations:
1. use the second radio channel as START control and perform the
necessary connections to the terminal board.
2. use the plug-in radio receiver.
EBP (fig.2).
The EBP electric lock with continuous service can be connected
directly to terminals 1 and 4.
14) SCRAPPING
Warning: This operation should only be carried out by qualified
personnel. Materials must be disposed of in conformity with the
current regulations. In case of scrapping, the automation devices do
not entail any particular risks or danger. In case of materials to be
recycled, these should be sorted out by type (electrical components,
copper, aluminium, plastic etc.).
15) DISMANTLING
Warning: This operation should only be carried out by qualified
personnel. When the control unit is disassembled to be reassembled
on another site, proceed as follows:
• Disconnect the power supply and the entire electrical installation.
• In the case where some of the components cannot be removed
or are damaged, they must be replaced.
The descriptions and illustrations contained in the present
manual are not binding. The Company reserves the right to make
any alterations deemed appropriate for the technical, manu-
facturing and commercial improvement of the product, while
leaving the essential product features unchanged, at any time
and without undertaking to update the present publication.
Téléchargé sur www.confort-electrique.fr
Retrouvez tous les produits du fabricant BFT sur notre site internet www.confort-electrique.fr
INSTALLATION MANUAL
instructions
Instructions
Retrouvez tous les produits du fabricant BFT sur notre site internet www.confort-electrique.fr
ENGLISH
ALPHA-ALPHA BOM - Ver. 06 -
11