Distance & Spot Size
As the distance (D) from the object increases, the spot size (S) of the area
measured becomes larger. The meter's D:S ratio is 10:1, so at 10 inches (254mm),
the diameter of the target being measured must be at least 1" (25.4mm).
inch
10
1.0
25.4
mm
254
Distance (D): Spot (S) = 10:1
(Typically, the spot size indicates 90% encircled energy)
Operation
1. Hold the meter by the handle grip and point the meter towards the object
being measured.
2. Pull and hold the trigger to turn the meter on. Read the temperature
reading on the display. If the display does not turn on, replace the battery.
3. Release the trigger and the HOLD display icon will appear on the LCD
indicating that the reading is being held.
a. In the HOLD mode, press the red "
b. Press the "
" button to turn the backlight on or off.
c. Press the °C/°F button to select measurement units in Fahrenheit or Celsius.
4. The meter will automatically power down after approximately 8 seconds
after the trigger is released.
5. With the trigger pulled, push the MAX/MIN button to record the highest
(MAX) and lowest (MIN) temperature readings. Push the MAX/MIN button to
cycle through the MAX reading, MIN reading and the current reading.
40
20
4.0
2.0
Sensor Beam
50.8
101.6
508
1016
" button to turn the laser on or off.
3 3
Operation cont.
NOTE:
• Make sure that the target is larger than the spot size displayed by the
Distance: Spot diagram printed on the side of the meter.
• If the surface area is highly reflective, apply electrical tape or flat black
paint to surface before measuring. Allow time for tape or paint to adjust
to temperature.
• The meter cannot measure through transparent surfaces such as glass.
It will measure the surface temperature of the glass instead.
• Steam, dust, smoke, etc., can block measurements.
• Make sure the surface being measured is free of frost, dirt, oil, etc.
• The meter automatically corrects for changes in ambient temperature.
However, it can take up to 30 minutes to adjust to wide variations.

Battery Replacement

1. The LCD will display a "
" replacement
symbol when it's time to replace the battery.
2. Note the two depressions on
either side of the meter near
the trigger.
Pull down from this spot to open
the battery cover.
Remove and safely discard the
old battery.
Replace with a new 9-Volt battery
and close the battery cover.
Low Battery
Indicator
Battery Cover:
Pull down to open
4