1. Quick Start guide
a) Connect DC cables to the charger and then the battery or batteries; ensure that there is a
good electrical connection and keep the terminals away from any surrounding objects that
could cause a short circuit.
b) Connect the AC power cable to a mains power outlet; the TEST LED will be illuminated or blink
when the Blue Smart Charger is powered up.
The TEST LED will continue to blink until a charge pulse is able to increase the battery voltage
above 12.5V (25.0V for 24V chargers) or 2 minutes have elapsed.
If a fault is detected during the test phase (such as a short circuit, reverse polarity or incorrect
charger voltage) all charge status LEDs will blink; in this case the charger should be immediately
disconnected.
c) Select the charge mode appropriate for the battery type; briefly press the MODE button to cycle
through the available options, the LED beside the currently selected charge mode will be
illuminated.
3