Please follow the steps 1-8 to replace the new battery:
2
9.
Use "cross" screw driver to remove the screws of the front panel.
10.
Pull the front panel out from the UPS.
11.
Remove the 4 screws as indicated above.
12.
Pull down the battery fastened plate as indicated.
13.
Pull out the battery tray a little.
14.
Remove the battery negative (-) end of the battery and make sure it won't be short with the battery positive (+).
15.
Remove the battery positive end, and then pull out the battery tray completely for new battery replacement.
16.
Repeat all the procedures in reverse way to finish the replacement task.
Please do not be reversed the RED (+) and black (-) of battery wire when you connect them to the terminal of
battery. • Once the battery is disconnected, the loads are not protected from power outages

4.2 Storage Instructions

The UPS should be stored in a cool dry location. Make sure the battery is fully charged before the UPS is stored. For
extended storage in moderate climates, the battery should be charged for 12 hours every 6 months by plugging the
power cord into the wall receptacle and turning on the main switch. Repeat every 3 months in high temperature
locations (more than 30°C).
5. Troubleshooting
The TROUBLESHOOTING TABLE in the next page covers most of the difficulties that you may encounter under
normal working conditions. If the UPS fails to operate properly, please review the following steps before calling the
repair center:
1. Is the UPS plugged into a proper working outlet?
2. Is the line voltage within the specified rating?
3. Does the fuse on the rear panel need to be replaced?
Please do not open the metal cover.
There are no user serviceable parts inside
The batteries contained in this UPS are recyclable.
The batteries contain lead and pose a hazard to the environment and human health if not disposed of
properly.
Do not open or mutilate the batteries. They contain an electrolyte which is toxic and harmful to the skin
and eyes.
A battery can present a risk of electrical shock and high short circuit current. When replacing batteries,
wrist watches and jewelry such as rings should removed. Use tools with insulated handles.
Please note the following information when you call for service: