TECHNICAL DATA
Parameter description
Parameter value
Product name
Pedicure chair
Model
LA PAZ
LA PAZ
WHITE
GREEN
Voltage [V~]/Frequency [Hz]
230/50
Rated power [W]
300
Protection class
I
IP Protection class
IPX0
Working mode
2 min „ON"/18 min „OFF"
Maximum load [kg]
175
Backrest adjustment angle [°]
0-77
Footrest adjustment angle [°]
0-74
Adjustment range of the
65-98
seating [cm]
Dimensions HxWxD [cm]
190x81x(65-179)
Weight [kg]
85,8
1. GENERAL DESCRIPTION
The user manual is designed to assist in the safe and
trouble-free use of the device. The product is designed
and manufactured in accordance with strict technical
guidelines,
using
state-of-the-art
technologies
components. Additionally, it is produced in compliance
with the most stringent quality standards.
DO NOT USE THE DEVICE UNLESS YOU HAVE
THOROUGHLY READ AND UNDERSTOOD THIS
USER MANUAL.
To increase the product life of the device and to ensure
a trouble-free operation, use it in accordance with this user
manual and regularly perform the maintenance tasks. The
technical data and specifications in this user manual are
up to date. The manufacturer reserves the right to make
changes associated with quality improvement.
Legend
The product satisfies the relevant safety
standards.
Read instructions before use.
The product must be recycled.
WARNING! or CAUTION! or REMEMBER!
Applicable to the given situation (general
warning sign).
Only use inside.
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details may
differ from the actual product.
The original operation manual is in German. Other
language versions are translations from German.
U S E R M A N U A L
2. USAGE SAFETY
ATTENTION! Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in an electric shock, fire and/
or serious injury or even death.
Whenever „device" or „product" are used in the warnings
and instructions, it shall mean Pedicure chair. Do not use in
very humid environments or in the direct vicinity of water
tanks. Prevent the device from getting wet. Risk of electric
shock!
2.1. ELECTRICAL SAFETY
a)
The plug has to fit the socket. Do not modify the
plug in any way. Using original plugs and matching
sockets reduces the risk of electric shock.
b)
Avoid touching earthed elements such as pipes,
heaters, boilers and fridges. There is an increased risk
of electric shock if the earthed device is exposed to
rain, in direct contact with a wet surface or operating
in a humid environment. Water ingression into the
device increases the risk of damage to the device
and of electric shock.
c)
Do not touch the device with wet or damp hands
d)
Use the cable only in accordance with its designated
use. Never use it to carry the device or to pull the
plug out of a socket. Keep the cable away from heat
sources, oil, sharp edges or moving parts. Damaged
or tangled cables increase the risk of electric shock.
e)
If using the device in a humid environment cannot
be avoided, a residual current device (RCD) should
be applied. The use of an RCD reduces the risk of
electric shock.
and
2.2. SAFETY AT THE WORKPLACE
a)
Make sure the workplace is orderly and well lit.
A messy or poorly lit workplace may lead to accidents.
Try to anticipate what may happen, observe what is
going on and use common sense when working with
the device.
b)
Do not use the device in an explosion hazard zone,
for example in the presence of flammable liquids,
gasses or dust. The device generates sparks which
may ignite dust or fumes.
c)
Upon discovering damage or irregular operation,
immediately switch the device off and report it to
a supervisor without delay.
d)
If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
e)
Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
f)
If a fire starts, use solely powder or carbon dioxide
) fire extinguishers suitable for use on live
(CO
2
devices to put it out.
2.3. PERSONAL SAFETY
a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which
can significantly impair the ability to operate the
device.
b)
The machine is not designed to be handled by
persons (including children) with limited mental
and sensory functions or persons lacking relevant
experience and/ or knowledge unless they are
supervised by a person responsible for their safety
Rev. 31.08.2018
6
or they have received instructions on how to operate the
machine.
c)
To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
2.4. SAFE DEVICE USE
a)
Do not overload the device. Exceeding the maximum
permissible user weight can damage the product.
b)
Do not use the device if the ON/OFF switch does not
function properly (does not switch the device on and
off). Devices which cannot be switched on and off
using the ON/OFF switch are hazardous, should not
be operated and have to be repaired.
c)
When not in use, store in a safe place, away from
children and people not familiar with the device, who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
d)
Maintain the device in a good technical state. Before
each use check for general damage and especially
check for cracked parts or elements and for any other
conditions which may impact the safe operation of
the device. If damage is discovered, hand over the
device for repair before use.
e)
Keep the device out of the reach of children.
f)
Device repair or maintenance should be carried out
by qualified persons, only using original spare parts.
This will ensure safe use.
g)
To ensure the operational integrity of the device, do
not remove factory fitted guards and do not loosen
any screws.
h)
When transporting and handling the device between
the warehouse and the destination, take into account
the occupational health and safety principles for
manual transport operations which apply in the
country where the device will be used.
i)
It is forbidden to move, adjusting and rotating the
device in the course of work.
j)
The device is not designed for store objects on it.
ATTENTION! Despite the safe design of the device
and its protection facilities and despite the use of
additional elements protecting the operator, there is
still a slight risk of an accident or injury when using
the device. When using the device stay alert and use
common sense.
3. USE GUIDELINES
Device is designed for providing cosmetic services, it
is equipped with electric adjustment of backrest and
seat. Footrest modification is also possible. The product
is outside the scope of MDD93/42/EEC regulations for
medical devices.
The user is liable for any damage resulting from
nonintended use of the device.
3.1 DEVICE DESCRIPTION
1.
Disassembled headrest
2.
Adjustable backrest
3.
Seat
4.
Basis
5.
Footrest
6.
Adjustable armrests
Rev. 31.08.2018
1
2
3
6
5
4
3.2. PREPARING FOR USE
Appliance location
Put the device on a stable, dry and flat surface, taking care
to keep a minimum space of 0,8 m around the device.
Before installation, the device must be placed close to the
power supply source.
Installing the appliance
In order to mount the armrests, it is necessary to start with
the left element:
Turn the pins of armrest upwards.
Turn the backrest upward so that the pin bolt head
will be at the top.
Insert the armrest in the hole in the body so that the
locking peg will be slid into the gap in the head of
the pin. Turn the element to the horizontal position.
7

Publicidad

Tabla de contenido
loading

Tabla de contenido