SPECIFICATIONS
Power supply
Liquid temp. range
Discharge size
Sump basin
NOTICE: Read this Owner's Manual for installation, operation, and safety information.
INSTALLATION
NOTICE:
Install pump on a hard, level surface (cement, asphalt, etc.). Never place pump directly on earth, clay or
gravel surfaces.
Piping – Effluent Applications (3/4" or Less Solids)
Piping must be 1-1/2" minimum to carry volume of pump discharge. Check local codes to determine if a check valve is
required in your system. In cold climates, check valves are not used to prevent effluent from freezing in piping.
If using as a sump pump, a check valve is recommended.
Piping – Sewage Applications (2"or Less Solids)
In any case, piping must not be smaller than pump discharge. When installed in a sewage system, pipe must be capable
of handling semi-solids of at least 2" (5.1 cm) diameter. The rate of flow in the discharge pipe must keep any solids
present in suspension in the fluid. To meet minimum flow requirements, the minimum pipe size is 2".
Use a 2" (5.1 cm) swing check valve in pump discharge to prevent backflow of liquid into sump basin. Check valve
should be a free flow valve that will easily pass solids.
NOTICE:
For best performance of check valve when handling solids, do not install it with discharge angled more than
45° above the horizontal. Do not install check valve in a vertical position as solids may settle in valve and prevent
opening on start up.
Drill a 1/8" (3.2mm) hole in discharge pipe about 1"-2" (2.5 - 5.1cm) above pump discharge connection (but below check
valve) to prevent air locking the pump.
For 40011-3/41011-3/41021-3/41041-3/41051-3 installation
40011-3 41011-3:115V, 60 HZ., 15 Amp Circuit
41021-3 41041-3 41041-2 41051-3 41051-2:115V, 60
HZ., 20 Amp Circuit
32-131°F (0-55°C)
2" FNPT
Minimum 22 in. (559 mm) diameter, 30 in. (760 mm)
depth
1/8" hole
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

41011-341021-341041-341041-241051-341051-2

Tabla de contenido