NATURAL GAS CONVERSION
Natural gas conversion must be performed only by your natural gas provider
or Service Company. Attempting to perform the natural gas conversion yourself is not
safe and may result in property damage, serious bodily injury or death.
Step 1- At the control panel, disconnect the rubber gas hose from the gas valve.
Step 2- Below the burner, disconnect the aluminum gas tube from the orifice elbow.
Step 3- Remove the 2 M4 nuts from the orifice holder and remove the orifice bracket
assembly.
Step 4- Disconnect the orifice from the elbow and replace it with the Natural Gas orifice from
the kit.
Re-fit the orifice bracket assembly onto the holder using the 2 M4 screw s and nuts. Re-
connect the aluminum gas tube into the end of the elbow. Connect your Natural Gas supply
line onto the gas valve at the control panel. BEFORE ATTEMPTING TO USE THE FIREPIT,
check ALL of the connections for leaks using a solution of soapy water. If a leak is discovered
and any bubbles are seen, close the main gas valve and re-tighten ALL the connections.
NEVER USE A FLAME TO CHECK FOR GAS LEAKS!
Page 11 of 43
P655-772