4.5
In the Venus model the ceramic must be simply placed in the top hole of the stove.
4.6.
Mandatory stainless steel pipe (AISI 316), never use aluminum, galvanized or iron pipe.
4.7.
In cases of humidity in the atmosphere above 60% is highly recommended installing a double-walled pipe of
stainless steel.
4.8.
If the stove is installed in a wooden house, the vertical pipe MUST be installed using double-wall insulation
and special attention should be paid to the area where it goes through the wall, isolated sockets are
mandatory.
4.9.
If the stove is mounted in a French style, a protective plate must be used to prevent a backflow of gases.
4.10. Aluminium belt and silicone of high temperature (300
4.11. Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.12. The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove's output. It is mandatory to install at least
two metres in length vertically to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1 metre; greater lengths mean ash, condensation or corrosion
may build up in this area.
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is
recommendable to install an uninterruptible power supply (UPS) which we have available as an option. This
apparatus only feeds the exhaust vent.
4.13. Distances from doors, Windows, ventilation grids or air input to the house or building:
MATERIAL REQUIRED FOR INSALLATION.
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
Drawing 2
C).
°
31