Exhaust circuit extractor.
Nuts and washers (5 units).
Ceramic fiber joint (replace).
When reassembling the exhaust it is COMPULSORY to replace the exhaust joint with a new one as you run
the risk of gas entering in our home.
5.10. Dismantling and Cleaning of gas outlet pipes.
When mounting the gas outlet pipeline, make sure it is well assembled, preferably sealed with silicone. If the
pipe has sealing joints, you must verify its good condition and replace it if necessary.
5.11. Lubrication of the brass tips of the endless shaft's upper and lower parts with lubricant oil; a small quantity is
enough for all the season. This operation is only recommended in the case of noise.
You get access to the lower tip from inside the hopper, you will see it clearly after removing all pellets.
In order to reach the upper tip, you have to dismantle the endless screw from the back side of the stove; this
shall be necessary only in case of noise as it has been lubricated at manufacturing, with a high quality
lubricant sufficient for many years.
Reducing motor of endless.
Brass fitting and lubrication point.
5.12. Cleaning of the pellets drop tube.
Use the brush provided by ECOFOREST to remove the dust until the end of the tube.
Cleaning brush.
Pipe of pellets fall.
5.13. Lubricate the screws and the glass door handle.
5.14. Review the glass door joints.
Review in detail any imperfections which may cause an air inlet. Replace them if necessary.
5.15. Cleaning the dirt which may be accumulated inside the stove, accessing through the back.
5.16. Empty the hopper to take remaining pellets out to avoid pellets absorb humidity.