Dimensions And Clearances; Venting Requirements - ELICA EAS422SS Guía De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LOCATION REQUIREMENTS
Product dimensions
I* - Metallic spacers
Spacers has to be
installed and used
when cabinet depth
is greater than 12".
F
B
A
A
B
C
D
E
F
G
H
I*
For gas and electric ranges installation: Mount this hood so
that the bottom edge is at minimum 30"(76.2 cm) above the
cooking surface.

Venting requirements

Vent system must terminate to the outdoors, except for no
vented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Rigid metal vent is recommended. Plastic or metal foil
vent is not recommended. The length of vent system and
number of elbows should be kept to a minimum to provide
efficient performance.
H
G
E
I*
D
C
I*
Model
EAS422SS
22
" (57 cm)
1
2
19
" (50 cm)
5
8
1
3
" (3.5 cm)
8
10¾" (27.3 cm)
9
" (24.2 cm)
17
32
" (.85 cm)
21
6 4
14
9
" (37 cm)
1 6
6" (15.2 cm)
½" (1.27 cm)
Installation clearances
B
C
E
F
A.
12" (30.5 cm) min. upper
cabinet height
B.
24" (61 cm) cabinet
opening width*
C.
30" (76.2 cm) suggested min.
bottom of cabinet to cooking
surface
*NOTE: This range hood is set to 24" (61 cm) cabinet width x
12" (30.5 cm) deep cabinets.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper.
Use caulking to seal exterior wall or roof opening around
the cap.
The size of the vent should be uniform.
A
D
D.
12" (30.48 cm) cabinet opening
depth*
E.
15" (38.1 cm) min. clearance
upper cabinet to countertop
F.
36" (91.4 cm) base cabinet
height
5