Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 35)
Flow diagram (see page 35)
Spare parts (see page 37)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
Cleaning (see page 37)
Operation (see page 38)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
max. 70°C / 4 min
Assembly (see page 32)
English