EU Declaration of conformity
We declare under our sole responsibility that this product corresponds to the
directives 2014/35/EU, 2014/30/EU, 2006/42/EG and 2011/65/EU and conforms
with the standards or normative documents: EN 61010-1, EN 6010-2-051,
EN 61326-1 and EN 60529.
A copy of the complete EU Declaration of Conformity can be requested at
sales@ika.com.
Safety instructions
• Read the operating instructions in full before starting up and follow the
safety instructions.
• Keep the operating instructions in a place where they can be accessed by everyone.
• Ensure that only trained staff work with the appliance.
• Follow the safety instructions, guidelines, occupational health and safety and ac-
cident prevention regulations.
• The voltage stated on the nameplate must correspond to the mains voltage.
EN
• The device must only be operated with the original plug-in power supply unit.
• Wear your personal protective equipment in accordance with the hazard cat-
egory of the medium to be processed. There is a risk of:
- splashing liquids
Page
- projectile parts
11
- body parts, hair, clothing and jewellery getting caught.
11
• Set up the appliance in a spacious area on an even, stable, clean, non-slip, dry
12
and fireproof surface.
12
• The feet of the appliance must be clean and undamaged.
13
• Position the knob (C) at the left stop before starting up. Gradually increase the
15
speed. Gradually increase the speed.
16
• Keep hand/arm vibration to a minimum (Directive 2002/44/EC) when operated
17
manually:
17
- Keep the sample container as vertical as possible.
- Only exert the minimum pressure necessary for the mixing process.
- Use attachments for multiple samples when there is a large number of samples.
• If the shaking movement of the appliance increases (resonance), reduce the
speed or pass through the critical phase as quickly as possible.
• Reduce the speed if:
- the medium splashes out of the vessel because the speed is too high
- the appliance is not running smoothly
- the appliance begins to move around because of dynamic forces.
• Firmly secure the accessories and vessels in place, otherwise shaking vessels
could be damaged or projected out.
• Check the appliance and accessories beforehand for damage each time you
use them. Do not use damaged components.
• Position one single shaking vessel in the centre and several shaking vessels so
that they are evenly spread out.
• Sharp edged vessels cause wear debris on the attachments.
• Beware of the risk of:
- flammable materials
- glass breakage as a result of mechanical shaking power.
• Only process media that will not react dangerously to the extra energy pro-
duced through processing. This also applies to any extra energy produced in
other ways, e.g. through light irradiation.
11