6. Replace all the parts, following the steps described above in the reverse
order.
! Take particular care when handling the spark plug wires and the
thermocouple pipes.
• Primary air regulation for the oven burner
The burner was designed not to need any adjustments to the primary air.
• Setting the oven burner to minimum
1. Turn the knob first to the Max setting for about 10 minutes and then to
Min.
2. Remove the knob.
3. Remove the disk fastened to the control panel.
4. Adjust the screw located outside the thermostat cock pin until the flame
is small but steady (the flame can be seen through the slots on the oven
bottom).
! If the appliance is connected to liquid gas, the regulation screw must be
fastened as tightly as possible.
! Once this procedure is finished, replace the old rating sticker with one
indicating the new type of gas used. This sticker is available from any of our
Service Centres.
! If the gas pressure is different from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe in accordance with current
National Regulations.
18
3. Unscrew the burner fastening screws.
4. Remove screw "V" and then the oven
burner.
5. Unscrew the oven burner nozzle using
the special socket spanner for the nozzles,
or better still a 7 mm socket spanner, and
replace it with a nozzle suited to the new
type of gas (see Table 1).
5. Make sure the burner does not switch off
when you turn the knob from Max to Min
quickly, or when you open and close the
oven door quickly.

DATA PLATE

width 43.1 cm
Dimensions
height 31.4 cm
depth 43.7 cm
Volume
59.1 l
Electrical
see data plate
connections
Gas features
see data plate
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 2004/108/EC of 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2009/142/EC of 30/11/09 (Gas)
and subsequent amendments.
- 2012/19/EU and subsequent
amendments.
- 1275/2008 standby/off mode.
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
ENERGY LABEL
EU Regulation no 66/2014
and
implementing Directive 2009/125/EC.
ECODESIGN
Standard EN 15181

Publicidad