Vibration Level; Battery Level - Rebel RB-5002 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
Output
Operation time
Cutting element
Cutting system
Line diameter
Line length
Cutting diameter
No load speed
Weight
In set
Sound pressure level L
Sound power level L
Hand-arm vibration

Vibration level

The vibration emission level stated in this instruction manual has been measured in
accordance with a standardized test given in EN 60745; it may be used to compare one
power tool with another and as a preliminary assessment of exposure to vibration when
using the power tool for the applications mentioned.
• Using the power tool for different applications, or with different or poorly maintained
accessories, may significantly increase the exposure level.
• The times when the power tool is switched off or when it is running but not actually
doing the job, may significantly reduce the exposure level. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the
power tool and the accessories, keep the hands warm, organization of work patterns.
OPERATION
Note: The battery is partially charged. To ensure proper operation of the power tool,
the battery must be fully charged before first use.

Battery level

To check the battery level press the button at the back of the battery:
• When the battery is fully charged, all three LEDs are on.
• When the battery is half empty, two LEDs are on.
• When the battery is empty, only one LED is on. Charge the battery immediately.
Charging
• Place the AC charger on a flat and stable surface within about 1 meter from the power
supply socket.
EN
21 V; 2,2 A
Up to 20 min
Dual-line trimmer head
Semi-automatic line feed
1,2 mm
5 m
22 cm
8000 rpm
2,1 kg
Side wheel, AC charger, battery, user's manual
72 dB(A), K= 3 dB(A)
PA
92 dB(A), K= 3 dB(A)
WA
6,918 m/s
K=1,5 m/s
2
2
40