Safety and operating instructions
Tightening torques
A
B
C
A.
Torque: 65-70 lbf.ft (88-95 Nm), use Loctite®
542™ (Loctite is a registered trademark of
Henkel Corporation. 542 is a trademark of
Henkel Corporation.)
Torque: 10-12 lbf.ft (14-16 Nm), use Loctite®
B.
270™ (Loctite is a registered trademark of
Henkel Corporation. 270 is a trademark of
Henkel Corporation.)
C.
Torque: 400 lbf.ft (540 Nm).
Troubleshooting
If the pneumatic machine does not start, has low
power or uneven performance, check the following
points.
Check that the insertion tool being used has the
♦
correct shank dimension.
Check that the pneumatic machine is getting the
♦
correct amount of lubricant. Too much lubrication
can cause starting problems, low power or
uneven performance.
Check that the compressed air system supplies
♦
the machine with sufficient air pressure to give
full power.
Check that the dimension and length of the air
♦
hose are according to the recommendations. See
"Installation".
If there is a risk of freezing, check that the
♦
machine's exhaust ports are not blocked.
If the machine function is still not satisfactory after
♦
this procedure, contact an authorised service
workshop.
16
Storage
>
Clean the machine properly before storage, in
order to avoid hazardous substances. See "Dust
and fume hazard"
>
Pour approximately
1
⁄
2
the air inlet nipple, connect the machine to the
compressed air supply and start it for a few
seconds.
>
Always store the machine in a dry place.
Disposal
A used machine must be treated and disposed of in
such a way that the greatest possible portion of the
material can be recycled and any negative influence
on the environment is kept as low as possible, and
in respect to local restrictions.
9800 0548 90b | Original instructions
CP 0012
oz (5 cl) of oil directly into