Troubleshooting Procedures (cont.)
Symptoms
3. Whirlpool stops automatically
before 18 minutes. (whirlpools
with optional timer kit only)
4. Whirlpool does not stop
automatically after 22 minutes.
(whirlpools with optional timer
kit only)
5.
Noisy operation.
6. Heater does not operate.
Kohler Co.
Probable Causes
A. GFCI or ELCB trips.
B. Air actuator hose is not
properly installed to optional
timer kit.
C. Suction is blocked.
D. Jets are blocked.
E. Motor overheated and
protection device activated.
A. Optional timer kit does not
work.
B. Wiring error.
A. Pump banding straps have not
been cut. (models with wooden
support blocks only)
B. Dry or dislodged jet O-ring
(squeal).
A. No power to heater.
B. Water temperature exceeds
104° F (40° C).
C. Heater does not work.
9
Recommended Action
A. Identify source of fault and
correct. If problem persists,
refer to installler/dealer.
B. Use timer kit installation
instructions to check timer kit
installation. Refer to
installer/dealer.
C. Remove obstruction.
D. Remove blockage.
E. Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
Check for suction blockage.
Remove blockage and allow
motor to cool.
Check for jet blockage. Remove
bloackage and allow motor to
cool.
A. Replace optional timer kit.
Refer to installer/dealer.
B. Refer to dealer.
A. Cut pump banding straps with
tin snips.
B. Remove jet, replace and
lubricate O-ring, and reinstall
jet.
A. Set/Reset GFCI or ELCB
breaker.
B. Allow water to cool; heater
will re-engage.
C. Replace heater. Refer to
installer/dealer.
1010564-5-G