Easy maintenance
Replaceable heating elements (3 pcs)
The steam generator has an overheating protector equipped with a reset button
The fill cap for limescale remover (citric acid) has been placed on a steam pipe of the steam generator cover (see
image on page 6).
Components (circuit board, heating elements, surface sensor) are easy to replace.
Accessories
-
Essence pump, (Essence pump kit 0038130)
-
Essence pump canister 20 l (0038132)
-
Automatic flush and rinse cycle. Automatic drain valve 4310130, (included in the Pro models)
Steam nozzles (3.4 – 6.0 kW 1 piece, 7.7 – 9.5 kW 2 pcs, 12 – 16 kW 3 pcs) (7819604)
-
General
Steam generators are only intended for use in heating spa facilities. Using steam generators in areas other than
steam rooms can damage the building's structure.
The manufacturer is not responsible for damages caused if the unit has been used incorrectly or in a manner for
which the unit was not designed.
Water and steam pipe connections must be made prior to connecting the unit into the mains.
Due care and attention must be taken when making the connections. Proper sealing must be ensured for all
extensions. A good extension must at least have taped-over twist connections, but it is recommended that
connections are soldered.
NOTE: Controlling the lights in the steam room with the circuit board is is only possible with resistive loads
(incandescent light bulbs). The circuit board relay cannot withstand capacitive loads (switched-mode power supply
units). If the lighting fixtures in the sauna have transformers, for example LED or halogen lamps, the steam generator
circuit board's relay control must be fitted with a separate relay or contactor for controlling the lights.
Operation of the steam generator controls
Refer to the specific control panel operating manual for the instructions.
Warnings
-
This appliance is not intended for use by persons (including children over the age of 8) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been instructed about
the safe use of the appliance and the risks involved. Children must not be allowed to play with the appliance or
to clean and service it without supervision. (7.12 EN 60335-1:2012)
-
The steam generator produces hot water vapour (100 °C) while in use.
-
Disconnect the appliance from the electrical supply before servicing and cleaning it.
-
Water connection pressure 0.2–1 MPa (2–10 bar)
Warning: Hot water vapour