Technical Specifications; Dimensions - clage CFX-U Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62
CFX-U FUNKTRONIC MPS ®

2. Technical specifications

Model
Energy efficiency class
Rated capacity (Rated current)
EN
Chosen capacity (Chosen current)
Electrical connection
Min. required cable size
Hot water (l/min)
max. at ∆t = 33 K
Rated volume
Rated pressure
Connecting type
Heating system
Required spec. waterresistance @ 15 °C
Spec. electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature choice
Water connection
Weight (when filled w. water)
VDE class of protection
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013
1) Mixed water
2) Flow rate limited to achieve optimum temperature rise
3) Without flow regulator
Model
Operating voltage
Type of battery
Type of protection
Transmission range
Transmission power
Transmission and receiving frequency range
Radiation
Approvals
1) Do not use rechargeable batteries.

3. Dimensions

CFX-U FUNKTRONIC MPS ®
A *
)
11 / 13,5 kW (16 / 19,5 A)
11 kW (16 A)
3~ / PE 380..415 V AC
1,5 mm
2
4,8
0,3 l
1.0 MPa (10 bar)
pressure resistant / pressureless
Bare wire heating system IES ®
≥ 1000 Ωcm
≤ 100 mS/m
≤ 70 °C
2,0 – 5,0 l/min
0,2 bar at 2,5 l/min
1,3 bar at 9,0 l/min
20 °C – 60 °C
G ⅜"
2,7 kg
I
FX Remote control
3 V
2x AAA Alkaline
IP 20
10 metres incl. barrier
< 10 mW
868.0 – 868.6 MHz
undirected
Europe EN 300 220 / CE
Dimensions in mm
16
13,5 kW (19,5 A)
2,5 mm
2
5,8
1)
2)
3)
IP24
1)

Publicidad

Tabla de contenido
loading

Tabla de contenido