Section 1 Introduction
Brooks
®
SFP

1-3 Performance Specifications

Table 1-1 Specifications SFP32/SFP33
Performance
Performance
Performance
Performance
Performance
Pressure Measurement
Pressure Measurement
Pressure Measurement
Pressure Measurement
Pressure Measurement
Accuracy
Accuracy
Accuracy
Accuracy
Accuracy
Temperature Compensation Range
Temperature Compensation Range
Temperature Compensation Range
Temperature Compensation Range
Temperature Compensation Range
Temperature Drift
Temperature Drift
Temperature Drift
Temperature Drift
Temperature Drift
Physical
Physical
Physical
Physical
Physical
Materials of Construction
Materials of Construction
Materials of Construction
Materials of Construction
Materials of Construction
Process Connections
Process Connections
Process Connections
Process Connections
Process Connections
Ceramic Sensor Proof Pressures
Ceramic Sensor Proof Pressures
Ceramic Sensor Proof Pressures
Ceramic Sensor Proof Pressures
Ceramic Sensor Proof Pressures
Leak Pressures
Leak Pressures
Leak Pressures
Leak Pressures
Leak Pressures
Functional
Functional
Functional
Functional
Functional
Pressure Output Signals
Pressure Output Signals
Pressure Output Signals
Pressure Output Signals
Pressure Output Signals
Voltage Input Requirements
Voltage Input Requirements
Voltage Input Requirements
Voltage Input Requirements
Voltage Input Requirements
Miscellaneous
Miscellaneous
Miscellaneous
Miscellaneous
Miscellaneous
Protection
Protection
Protection
Protection
Protection
EMC Directive 89/336/EEC
EMC Directive 89/336/EEC
EMC Directive 89/336/EEC
EMC Directive 89/336/EEC
EMC Directive 89/336/EEC
* Note: 150 psi and 145 psi ranges are available only in the Ultrapure Water Models 32 WA and 33 WA.
1-2
Standard Ranges: 0-150 psi*, 0-145 psi*, 0-100 psi, 0-95 psi, 0-60 psi
Gauge pressure measurement is standard. Absolute pressure measurement is an option.
±1% full scale includes linearity, hysteresis and repeatability
Process Wetted: High purity perfluoroalkoxy PFA plastic
Proof pressure of the ceramic diaphragm is the maximum exposure pressure without damaging the sensor performance.
Minimum pressure at which the transmitter might leak.
4 - 20 mA, 0 - 5 V, 1 - 5 V and 0 - 10 V are available for pressure measurement in the range specified.
24 Vdc for current output; 12 - 24 Vdc for voltage output
Pressure Equipment Directive 97/23/EC as Sound Engineering Practice (SEP)
Installation and Operation Manual
SFP32/SFP33
SFP32/SFP33
SFP32/SFP33
SFP32/SFP33
SFP32/SFP33
15 - 40°C (59 - 104°F)
±0.3% full scale per degree C
Electrical Enclosure: Polypropylene
Pressure Sensor: AL
O
2
3
Process Connections: PFA tube stub is standard
Options: Male Flaretube (See Model Code)
Range
Proof Pressure
0 - 60 psig
112 psig
0 - 95 psig
178 psig
0 -100 psig
178 psig
0 -145 psig
187 psig
0 - 150 psig
187 psig
Range
Leak Pressure
0 - 60 psig
180 psig
0 - 95 psig
375 psig
0 -100 psig
375 psig
0 -145 psig
375 psig
0 - 150 psig
375 psig
IP55 equivalent. Meets CE standards