I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
–
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction.
• Press 5 to select:-
AUTO
AUTO
•
For COOL/DRY operation.
Swing up/down automatically.
•
For HEAT operation
AUTO
(For Heat Pump Model only)
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows at horizontal
level. As the temperature rises, the hot
air blows in a downwards direction.
I Setting the Horizontal Airflow Direction.
• Press 6 to select:-
Indoor
Horizontal
Unit
Airflow
Direction
Remote
AUTO
Control
•
For COOL/DRY operation.
AUTO
Swing left/right automatically.
•
For HEAT operation
AUTO
(For Heat Pump Model only)
There is no air swing during the discharge
air temperature is low. When the
temperature rises, the horizontal airflow
louvers swing left/right automatically.
G Use this air conditioner under the following
conditions:
Cooling Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature
32
23
Minimum Temperature
16
11
Heat Pump Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature-Cooling
32
23
(Maximum Temperature-Heating)
(30)
(-)
Minimum Temperature-Cooling
16
11
(Minimum Temperature-Heating)
(16)
(-)
G Notes
•
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
•
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
G Operation Details
COOL – Cooling Operation
•
To set the room temperature at your preference
cooling comfort.
(Unit in °C)
AUTO – Automatic Operation
•
Sense indoor temperature to select the optimum
Outdoor
mode.
DBT
WBT
•
Temperature is not displayed on the remote control
during AUTO operation.
26
43
11
16
DRY – Soft Dry Operation
•
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
•
During Soft Dry operation, the indoor fan operates at
Low fan speed.
(Unit in °C)
HEAT – Heating Operation
(for Heat Pump Model only)
Outdoor
•
Heat is obtained from outdoor air to warm up the
DBT
WBT
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
43
26
(24)
(18)
reduced.
•
Defrosting Operation
16
11
Depend on the outdoor temperature, the operation
(-5)
(-6)
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
•
When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
2°C below the set temperature.
(It is useful when using a heater).
6