Volume/Tone Push Button
The Volume/Tone Push Button
Figure
pressed:
NOTE
Table 1. Volume/Tone Push Button Functions
PRESS
DURATION
Momentary (when
scanner is asleep)
Momentary (when
scanner is awake)
Hold, then release
when the beeper
sounds
4 Seconds
8 Seconds
a. By standard default, this function is normally disabled to prevent accidental activation by users.
b. Users should not perform scanner resets except under the direction of trained systems support personnel.
Quick Reference Guide
2c) also performs multiple functions depending upon the duration of time it is
Volume changes made using the Volume/Tone Push Button are
lost when the scanner is powered-down and are reset to the
configured setting. If you wish to permanently change the vol-
ume, use the special programming labels in the Product Refer-
ence Guide.
FUNCTION
Wakes scanner from Sleep Mode
Increments volume
Increments tone
a
Scanner Diagnostics Mode
b
Resets Scanner
(Figure
2d — accessed by removing the Top Cover
Alternatively, the scanner can be awakened by:
- Moving an object through the scan zone.
- Scanning with an attached auxiliary scanner.
Press the push button momentarily to increase speaker volume.
When the loudest volume is reached, a repeated press of the
push button cycles volume back to the lowest setting, then vol-
ume increases on subsequent press(es). Four volume levels are
available.
Press the push button for approximately 2 seconds, then
release. Each time this is done, the beeper will sound at one of
three tones. Stop when the desired tone (high, medium or low) is
sounded.
This mode allows system support personnel to troubleshoot
problems with the scanner and is used to determine if it can read
bar codes. Press the button for eight seconds or cycle power to
exit Scanner Diagnostics Mode and reset the scanner.
Only system support personnel should perform a reset.
COMMENT
3