1.2 Safety warning

Important

This product be installed by a qualified professional.
All maintenance must be carried out by a qualified elec-
trician.
A minimum distance of 0,5m must be maintained be-
tween the equipment and a combustible surface.
The product must always be operated in a well ventilat-
ed area.
DO NOT stare directly into the LED light source.
Always disconnect the power before carrying out any
maintenance.
The earth must always be connected to the ground.
Ensure that all parts the equipment are kept clean and
free of dust.
2. Installation
2.1 Mounting
Hanging - The fixture can be mounted in a hanging position
using the supporting bracket. The bracket should be secured
to the mounting truss or structure using a standard mounting
clamp. Please note that when hanging the unit a safety cable
should also be used.
Upright - The fixture can be mounted in an upright sitting
position using the supporting brackets.
PROTON IP
ENGLISH VERSION
2.2 power connections
@220V: 50 units may be connected in series
@120V: 25 units may be connected in series
2.3 setting up with a DMX521 controller
Connect the DMX512 controller to the units in series.
Each unit has 13 DMX channels so the DMX Addresses
should increase by increments of 1, (Nx1) + 1, (Nx2) + 1,
(Nx3) + 1, ....
The ID address has not been set so therefore when using
the controller CH 10 must be inactive (CH10=0).
It is also possible to deactivate ID address selecting [ID
OFF] from the [Settings] menu, on the fixture.
Each DMX Address may be used as many times as required.
Any DMX address in the range from 001 to 512 may be used.
Example
The fixture above shows a simple DMX512 layout with the
starting address of the first unit set at 1, with the second set at
(Nx1)+1and so on...
(Note that when used in this way, the Ch10 ID function must be
inactive (CH10=0))