1.2 Safety warning
Important
•
This product be installed by a qualified professional.
•
All maintenance must be carried out by a qualified elec-
trician.
•
A minimum distance of 0,5m must be maintained be-
tween the equipment and a combustible surface.
•
The product must always be operated in a well ventilat-
ed area.
•
DO NOT stare directly into the LED light source.
•
Always disconnect the power before carrying out any
maintenance.
•
The earth must always be connected to the ground.
•
Ensure that all parts the equipment are kept clean and
free of dust.
2. Installation
2.1 Mounting
Hanging - The fixture can be mounted in a hanging position
using the supporting bracket. The bracket should be secured
to the mounting truss or structure using a standard mounting
clamp. Please note that when hanging the unit a safety cable
should also be used.
Upright - The fixture can be mounted in an upright sitting
position using the supporting brackets.
PROTON IP
ENGLISH VERSION
2.2 power connections
@220V: 50 units may be connected in series
@120V: 25 units may be connected in series
2.3 setting up with a DMX521 controller
•
Connect the DMX512 controller to the units in series.
•
Each unit has 13 DMX channels so the DMX Addresses
should increase by increments of 1, (Nx1) + 1, (Nx2) + 1,
(Nx3) + 1, ....
•
The ID address has not been set so therefore when using
the controller CH 10 must be inactive (CH10=0).
•
It is also possible to deactivate ID address selecting [ID
OFF] from the [Settings] menu, on the fixture.
•
Each DMX Address may be used as many times as required.
•
Any DMX address in the range from 001 to 512 may be used.
Example
The fixture above shows a simple DMX512 layout with the
starting address of the first unit set at 1, with the second set at
(Nx1)+1and so on...
(Note that when used in this way, the Ch10 ID function must be
inactive (CH10=0))
p. 3