Left LED
Right LED
None
None
None
Green
Flashing yellow
Green Link established and CobraNet activity detected; The unit is acting as a CobraNet Performer
Flashing yellow Flashing green Link established and CobraNet activity detected; The unit is acting as a CobraNet Conductor
Flashing yellow
None
Device ID switches
The VA-2060(e) and VA-4030(e) units represent separate Vocia device types. A VA-2060 and a VA-
2060(e) represent the same device type, as does the VA-4030 and VA-4030e.
The rotary ID switches give the unit a unique Device ID. The switches are in hexadecimal format. All units
of the same device type must have a unique Device ID to function properly within a Vocia Paging World.
The Factory Default Device ID is 01. A Device ID of 00 is invalid and cannot be used.
To assign a Device ID of hex 07, leave the MSB switch on 0 and turn the LSB switch to 7. Device ID
switches should be set using a 0.1 inch (2.5mm) to 0.12 inch (3.0mm) flat blade screwdriver.
Changes made to the Device ID while connected to the network require a power cycle of the device in order to take effect.
Analog Audio Inputs with Phantom Power option
For the VA-2060e and VA-4030e, each amplifier channel has analog inputs that allow a local balanced
microphone or line level background source to be delivered to the amplifier channel associated with that
input. Two such inputs are available on the VA-2060e amplifier and four on the VA-4030e. Input
sensitivity and 48V phantom power on/off state may be determined in the Vocia software. Because a local
input may only be delivered to the channel associated with that input, if a local background source is
required on two or more channels the source must be wired in parallel to each of the inputs. An exception
is that if two or more channels of an amplifier are configured in software as a group or multi-way, the
lowest local input channel number will be presented to all channels. For instance, if a VA-4030 is
deployed with channels 2, 3 and 4 configured as a group or 3-way multi-way, local input 2 will be
presented to outputs 2, 3 and 4.
Page Active Relays
Page Active Relays (PAR) are available on all amplifiers. Via the Page Active Relay connectors, one
Form C (single pole, changeover) relay is presented per channel for the VA-4030 and VA-4030e.
Similarly, two such relays per channel are presented for the VA-2060 and VA-2060e (relays operate in
tandem). Each PAR connector is a six-way 3.5mm pluggable screw terminal block. The PAR connections
are labeled as follows:
No Data Connectivity or CobraNet activity
CobraNet fault. Check cabling and configuration for errors