6. Turn the focus ring slowly counter-clockwise until the status indicator flashes green
or amber (not red).
7. To exit the Focus Assistant, press the function button again. The Focus Assistant is
switched off automatically after 15 minutes.
8. Retighten the lock screw for the focus ring.
9. Open the Live View page in the web browser and check the quality of the image.
10. On the Focus page, click Fine-tune focus automatically and wait until automatic fine
tuning is completed.
11. Click Enable iris. If the button is inactive the iris is already enabled.
12. If needed, make further adjustments under the Advanced tab. See the online help for
more information.
Reset to Factory Default Settings
Important
Reset to factory default should be used with caution. A reset to factory default will reset
all settings, including the IP address, to the factory default values.
Note
The installation and management software tools are available from the support pages
on www.axis.com/techsup
To reset the product to the factory default settings:
1. Disconnect power from the product.
2. Press and hold the control button and reconnect power. See Hardware Overview on
page 10.
3. Keep the control button pressed for 15–30 seconds until the status LED indicator flashes
amber.
4. Release the control button. The process is complete when the status LED indicator turns
green. The product has been reset to the factory default settings. If no DHCP server is
available on the network, the default IP address is 192.168.0.90
5. Using the installation and management software tools, assign an IP address, set the
password, and access the video stream.
It is also possible to reset parameters to factory default via the web interface. Go to Setup >
System Options > Maintenance and click Default.
Further information
•
For the latest version of this document, see www.axis.com
•
The user manual is available at www.axis.com
•
To check if there is updated firmware available for your product, see
www.axis.com/support
AXIS Q1615-E Mk II Network Camera