4.3
Pneumatic connection
1. Connect the TCE 4460 to the compressed air supply
unit.
2. Adjust to a pressure between 8 and 12 bar.
« Pull the red knurled screw (pressure reducing val-
ve) fi rst upwards and then twist it to adjust ope-
rating pressure.
« Check pressure on the manometer.
Robert Bosch GmbH
Initial commissioning | TCE 4460 | 33
4.4
Electrical connection
1. Check the correspondence of the mains tension and
the tension shown on the identification tag.
2. Ask a qualified electrician to mount a connection
plug for single-phase or (depending on the tension
you have ordered ) three-phase current (see the
electrical connections diagram inside the electrical
panel).
i
The costs of arranging a mains protection device for
the plug are borne by the customer.
3. Protect the TCE 4460 according to specific national
rules.
4.5
Check rotation direction
!
For a correct functioning of TCE 4460 it is extremely
important that, when the locking flange pedal shown
in Fig. 2 (1) is pressed, the locking flange (Fig. 2)
rotates clockwise.
1
Fig. 2:
Check rotation direction.
en
|
1 695 105 428
2010-02-16