FEATURES OF THE DELIVERY PIPES

In consideration of the high pressures employed, the delivery pipe must be designed and built with
materials suitable for such working conditions.
The same applies for any accessories installed.
When designing the system take into consideration the pressure drops along the line.
To limit the pulsating loads, typical of piston pumps, install a suitable damper or flexible pipe
(minimum 1.5 m long) between the pressure regulator and pump connection.
The accessories listed below must be used on the pump's circuit. Each accessory shall be correctly
dimensioned/rated and meet the requirements of current standards:
• Gauge
• Safety valve
• Pressure regulator valve, manual or automatic
• Antipulsation damper
DIAMETER
REDUCTION
36
All manuals and user guides at all-guides.com
90° CURVES
"T" CONNECTIONS
OVERTURNED "U" CURVES
BYPASS RECIRCULATION DURING SUCTION
NEGATIVE HEAD
TANK
TANK
SAFETY VALVE
TANK WALL
FILTER
BY-PASS LINE
YES
ACCUMULATOR
PRESSURE GAUGE
SAFETY VALVE
PUMP HEAD
FILTER
NO
ACCUMULATOR
PRESSURE GAUGE
PUMP HEAD
VALVE
OUT
BY-PASS
VALVE
OUT
BY-PASS
Fig. 08