INSTALLATION INSTRUCTIONS (CONTINUED)
Lubrication
This unit contains no oil.
Before operating compressor, fill to the
center of the sight gauge (see Figure 6).
Using any other type of oil may
shorten pump life and damage valves.
Recommended Oil (2 Options)
FSC-1000A ISO-100 Premium Reciprocating
Compressor Lubricant
1 quart part number FSC-1000A-1
12 quart case part number FSC-1000A-12
For generic option use 10W30
Oil Capacity
Approximately 8.5 oz.
Fill the pump with oil to the center of the sight gauge using oil
fill opening (see Figure 6).
Do NOT fill the pump through the
breather cap opening as this may cause oil to leak and spray out
during operation.
NOTE: Some residual oil may still be in the pump from factory
testing leaving a thin coat on the sight gauge; however, there
is not enough oil to operate the unit.
OPERATING INSTRUCTIONS
IMPORTANT: Check motor rotation before operating the
compressor.
All lubricated compressor pumps discharge some condensed
water and oil with the compressed air. Install appropriate
water/oil removal equipment and controls as necessary for the
intended application.
Failure to install appropriate
water/oil removal equipment may result
in damage to machinery or workpiece.
Guarding
The belt guard provided must be
installed before operating the unit.
All moving parts must be guarded. All electrical covers must be
installed before turning on the power.
Oil Drain
Plug
Sight Gauge
Figure 6 - Lubrication
10
Oil FIll
Area
Full
Low