Configuration

Settable parameters:
- Running pressure.
When the pressure in the
system falls below the Pm,
PRESFLO
starts-up the pump.
®
The Pm should always be
higher by at least 0.2 – 0.3
bar of the pressure genera-
ted by the column of water
overlooking PRESFLO
.
®
The Pm value can be carried
in the field between 1 bar and
5 bar.
Disposal
When disposing of any
PRESFLO
parts, adhere
®
to the relevant laws and
regulations in force in
the country in which the
equipment is being used.
Do not dispose of any
polluting parts in
the environment.
Manufacturer's setting:
PRESFLO
is supplied with the
®
following STANDARD CONFIGU-
RATION:
- Running pressure
Pm = 2 ( bar )
Configuration
The adjustment of the starting
pressure (Pm) is done by me-
ans of trimmer shown in FIG.
Statement of Compliance: we declare, under our own respon-
sibility, that the product in question is in compliance with the fol-
lowing European Directives and national implementation provisions
2014/35/CE Low Voltage Directive
2011/65/CE (RoHS)
2012/19/CE - 2003/108/CEE (WEEE)
2014/30/CE Electromagnetic Compati-
bility Directive (EMC)
EN 60730-2-6
EN 61000 6-3
1. Remove the small screwdri-
ver and adjust the trimmer on
the desired limits, according to
the values shown on the plate
located under the screwdriver.
Bigarello 01.06.16
DGFLOW S.r.l.
President
Stefano Concini
2. The start-up pressure can
be adjusted continuously from
1 to 5 bar (trimmer A)
3. When you finish adjustment
close the cover
Made in Italy by
DGFLOW srl Via Emilia, 5
46030 Bigarello (Mantova) Italy
tel. +39 0376 340922
fax. +39 0376 249525
info@dgflow.it - www.dgflow.it