STEP 1
Insert the needle in the hole. Bring out the needle 20cm.At the flush-fitting piece end, strip
the front panel electrical cable along 4 to5 cm, cut the shielding to remove excess thickness,
and tape the two parts securely, mid-length of it. Guide the assembly through the pipe while
another person pulls the needle.
STEP 2
Separate the two parts when they emerge from the pipe. Strip one the needle along 7 cm so
that it can be inserted into the pneumatic tube. Tape this assembly securely and thread the
pneumatic tube through the pipe again. Guide the assembly through the pipe whilst another
person pulls the needle. Bring the pneumatic tube up above the water level.
JET VAG
A ø10 drill is provided in the package. With this tool you have to enlarge
the hole of the part to be sealed through which you will pass the
pneumatic control pipe and also the power supply wire of the facade. (It
is possible that this operation has already been performed on the sealing
part)
Keep the drill straight
needle
front panel
pneumatic
tube
electrical
cable
needle
needle