Press the ON/OFF button (pic.1) or wipe slowly over the power button with hand by keeping a distance
of 3-5cm (pic.2) to turn on or turn off the appliance. Every operation is accompanied by a sound.
The appliance starts in automatic mode with a 60 seconds countdown which is use for one-time
analysis of the air quality after connecting to the power supply. After the countdown the LED display
shows the current PM2.5 value and activates the negative ion function. In addition, the VOC sensor is
activated after a 320 seconds countdown. When pressing the on/off button again, the appliance will
enter the standby mode, if you turn the appliance on again within five minutes from standby mode.
The PM2.5 and VOC values will be shown directly.
Pic. 1
The appliance features a filter exchange indicator (pic.4). After 2000 operation hours a flashing indica-
ting light will show on the LED display which indicates that the filter needs to be changed. Please note
that the operation time is rounded up to the next half hour. Example: If you have used the appliance
for 40 minutes, it will be counted as 1 hour. To reset the operation time counter after exchanging the
filter, press and hold the ON/OFF button as well as the FAN SPEED button for 3 seconds together.
The indicating light will flash 6 times during the reset and turn off.
At working mode, press the FAN SPEED button for 3 seconds to lock all buttons on the panel and
remote control, the same operation can unlock it.
Pic.2
20
Pic.3