Open the key:
1.Plug in the power cord, flip the rocker switch, the boot key display low light, click on the
switch to boot, if not for other operations, default to high-grade mode (default temperature
of 24 °c) , mode key highlight, digital tube middle display "3" , three seconds to digital
display setting temperature.
2.Press the key again and the product enters the standby state.
3.Press and hold the key to turn on the power supply to enter the self-test, the display
screen will be extinguished after 2 seconds, and the high and low heating tubes will be
heated for 2 seconds and then return to standby.
4.It acts as a switch in the normal state, and the machine remembers the pre-shutdown
state without power off (the timing function is not memorized).
Mode key:
1. In the boot state, click this button to switch the machine heating mode, power on for the
first time, the default high-end (default temperature 24 ℃), the switching order is high,
medium, low and high. Loop, the middle of the three-digit tube displays "3" 2 "1" 3 in turn. "
Cycle.
2.. When the mode is set, the button / key is also activated and highlighted, and clicking
the button / key can also increase or decrease the gear.
3. When the mode is set and after it is set, the indicator light in the middle of the mode key
is highlighted, the middle bit of the Nixie tube shows the current setting gear, and the Nixie
tube shows the setting temperature after 3 seconds.
4. Among them, the low, medium and high modes are the gear mode. when in these three
modes, the temperature can be set in the range of 7mur35 ℃, and the current setting gear
of the heating tube can be controlled according to the setting temperature and the tem-
perature of the NTC probe. The method is: first press the temperature key, and then press
the temperature / key to set the control temperature of the current mode, automatically
confirm after 5 seconds of no operation or directly click the temperature key to confirm.
Timing key:
1. Click the timing button to enter the timing shutdown setting, the indicator light in the
middle of the timing key is highlighted, and the time content is displayed by a three-digit
digital tube, the first two bits show the hour, and the last one shows "h".
2. Adjust the time by pressing the button / key, and confirm automatically after 5 seconds
of no operation or press the timing key directly (the maximum setting is 24 hours and 0
hours is no time).
3. No matter what heating mode the machine is in, it can be set to shut down at a fixed
time.
4. When the timing is set and after it is set, the indicator light in the middle of the timing
key is highlighted (when the timing is set to 0, when there is no timing, the timing indicator
is low);
5. Timing confirmation within 3 seconds after the Nixie display timing shutdown time, 3
seconds after the Nixie display setting temperature.