To change the cartridge
If water leaks from the spout aerator when the lever is in the "off" position,
the cartridge should be changed.
– Turn off the water supply. Check that the water supply is turned off by
opening the faucet.
– Remove the lever.
– Unscrew the hub (5). (The hub of the lavatory faucet is removed e.g. with
a small screw driver.)
– Unscrew the locking nut (6) (wrench opening 38mm).
– Replace the lever and the screw (2) and pull out the cartridge (7) with
the aid of the lever. Replace the cartridge with a new one.
– If the old cartridge is equipped with an ejector (3) insert the loose
ejector supplied into the hole of the sealing box (9) of the new cartridge. *)
– When replacing the cartridge the pin (8) should be in the slot.
– Assemble the faucet in reverse order.
*) An ejector is used in every lavatory faucet with hand shower, brush and
spray attachment.
To clean the ejector
The ejector should be cleaned if water flow is reduced or if water leaks from
the spout aerator at the same time when the trigger of the Bidetta hand
shower is pressed:
– Remove the cartridge according to the instructions above and remove
the sealing box (9) from the cartridge.
– Clean the ejector (3) and reassemble the faucet.