Descargar Imprimir esta página
HIKVISION Pyronix XDL15TT-AM Manual Del Usuario
HIKVISION Pyronix XDL15TT-AM Manual Del Usuario

HIKVISION Pyronix XDL15TT-AM Manual Del Usuario

Publicidad

Enlaces rápidos

L15
15m Pet Immune External Detector
Environmental Class IV
9.9GHz:
10.525GHz:
AT BE CH CY CZ DK FI
BE CH CY DK HU IE IS
FR GR HR HU IE IS IT
IT MT NL NO SE SI
LT MT NL PL SI TR
10.587GHz:
GB only
E N G L I S H
(diagram references)
Anti-Masking: The XDL15TT-AM uses the patented Anti-Masking technology
to detect when one or both PIR detectors as well as the Microwave module are
Masked. The detector is able to detect aluminium foil, spray and any object
positioned on or in front of the detector with the purpose of obstructing the
field of view of the PIR or MW sensors.
The masking area is adjustable between 0 to 1M.
The following describes the masking function in a disarmed state:
The instant that the masking area (see A1) is entered, the Blue LED starts
pulsing. Once the masking area has been vacated, the detector must see
activations (on all 3 of its sensors) in the main detection area, or the MASK
and ALARM relay will open and the Green and Orange LEDs will be activated.
To reset the detector back to normal operation, remove any obstructions in
the masking area and then return to the main detection area and move about
for 30-60 seconds.
Please see the symbol key below, in order to understand diagram A2:
Masking not
Scanning
Removing obstacle
detected
/analysis
(e.g. cleaning lens)
The Anti-Masking can be disabled when the panel is armed. To do this the
RI terminal has to be connected to an output of the panel that is POSITIVE
when ARMED and NEGATIVE when DISARMED. To enable this feature, switches
2 and 4 must be OFF.
Blocking: This feature allows the detection of obstruction located at 10M
or less and is used when the panel is disarmed. When the blocking feature is
active the Alarm relay will open and the Green and Orange LEDs will be
activated. To reset the blocking XD should be walk tested so that both PIRs
and MW sensors are activated.
To enable the feature, switches 3 and 4 must be OFF and the RI input
should be connected to an output on the control panel which gives a
NEGATIVE when DISARMED and a POSITIVE when ARMED.
Technical Specification
Tri-Detection: 2 dual element passive IR sensors & a microwave doppler unit;
Sensitivity Selectable: AUTO or HIGH
Pet Immunity: <24kg
Temperature Compensation: Digital
Detection Speed: 0.25 - 2.5m/s
Emissions EN55022 Class 2
Tri-Masking:
Adjustable from 0M to 1M. Covers all 3 technologies
Casing:
3mm polycarbonate, 0.4mm HDPE in Lens Area
Lenses:
2 x Lens 4 (UV Compensated)
Operating Voltage & Current:
9-16VDC, (24mA @ 13.8VDC quiescent)
Relay Output:
3 x SELV limits, 60VDC 50mA (42.4VAC peak)
Mounting Height & Range:
1.0M - 1.3M = 15M range (Lens 4)
Tamper Switches:
12VDC 50mA both front and rear
Temperature:
-40°C to +80°C (storage) -30°C to +70°C (operating)
Dimensions & Weight:
188 x 77 x 84mm, 0.3kg
Warranty
This product is sold subject to our standard warranty conditions & is warrant-
ed against defects in workmanship for a period of 5 years (excluding lens).
In the interest of continuing improvement of quality, customer care and
design, Pyronix Ltd reserves the right to amend specifications, without prior
notice. For full warranty information see www.pyronix.com/warranty
Product Warning Information
For electrical products sold within the European Community. At the end of
the electrical products life, it should not be disposed of with household
waste. Please recycle where facilities exist. Check with your Local Authority
or retailer for recycling advice in your country.
Optional Accessories
XD-FIXEDBRACKET
XD-WALLBRACKET + XD-45D-ADAPTER
Frequency
This product operates in a European non-harmonized
frequency band. Hereby, Pyronix, declares that this
XDL15TT-AM is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.
Visit
www.pyronix.com/product-compliance.php
for the declaration of conformity.
 0845 6434 999 (UK). +44(0)1709 535 225
All manuals and user guides at all-guides.com
START
Masking
detected
3
3EOL
XDL15TT-AM
3k
15k
12k
8k2
6k8
5k6
EOL
EOL
EOL R1
LED ALARM N/O
4k7
TAMPER
ALARM N/C MASK/FAULT
2k2
1k
10k
10k
5k6
6k8
4k7
5k6
4k7
3k9
3k9
2k7
2k2
2k7
1k5
2k2
A
A
T
T
+12V 0V
1k5
1k
EOL INPUT 1
1k
IP Rating: IP55
PCX 46
820R
Max: 1M
 customer.support@pyronix.com
W = XD-WALLBRACKET
F = XD-FIXEDBRACKET
MASK/ALARM LINK
2
DEOL
XDL15TT-AM
XDL15TT-AM
3k
15k
12k
8k2
6k8
5k6
EOL
EOL
EOL R1
LED ALARM N/O
4k7
TAMPER
ALARM N/C MASK/FAULT
2k2
1k
10k
10k
5k6
6k8
4k7
5k6
4k7
3k9
3k9
2k7
2k2
2k7
1k5
2k2
A
A
T
T
+12V 0V
1k5
1k
+12V 0V
EOL INPUT 1
1k
PCX 46
820R
30%
1M
30% Mask
MAX
OFF
>1m
≤1m
 www.pyronix.com
Pyronix Limited, Secure House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
N/C
2
XDL15TT-AM
3k
15k
12k
8k2
6k8
5k6
EOL
EOL
EOL R1
LED ALARM N/O
4k7
TAMPER
ALARM N/C MASK/FAULT
EOL
EOL
2k2
TAMPER
ALARM N/C MASK/FAULT
1k
10k
10k
5k6
6k8
4k7
5k6
4k7
3k9
3k9
2k7
2k2
2k7
1k5
2k2
+12V 0V
A
A
T
A
A
T
T
1k5
1k
EOL INPUT 1
EOL INPUT 1
1k
PCX 46
PCX 46
820R
XDL15TT-AM
EOL
TAMPER
+12V 0V
PCX 46
PCX
OFF
DEOL
N/C
XDL15TT-AM
3k
15k
12k
8k2
6k8
5k6
EOL R1
LED ALARM N/O
EOL
EOL
EOL R1
LED ALARM N/O
4k7
TAMPER
ALARM N/C MASK/FAULT
2k2
1k
10k
10k
10k
5k6
6k8
6k8
5k6
4k7
5k6
4k7
3k9
4k7
2k7
3k9
3k9
2k7
2k2
2k7
1k5
2k2
2k2
T
1k5
1k
A
A
T
T
+12V 0V
1k5
1k
EOL INPUT 1
1k
820R
820R
PCX 46
3k
15k
12k
8k2
6k8
5k6
4k7
2k2
1k
EOL
EOL R1
LED ALARM N/O
ALARM N/C MASK/FAULT
10k
10k
6k8
5k6
4k7
5k6
3k9
4k7
3k9
2k7
2k2
2k7
2k2
1k5
1k
1k5
1k
820R
No resistors are required for
the Alarm N/O relay
RINS1761-2
ATE INPUTS
3k
15k
12k
8k2
6k8
5k6
4k7
2k2
1k
10k
5k6
4k7
3k9
2k7
2k2
1k5
1k

Publicidad

loading

Resumen de contenidos para HIKVISION Pyronix XDL15TT-AM

  • Página 1 All manuals and user guides at all-guides.com START 15m Pet Immune External Detector Environmental Class IV 9.9GHz: 10.525GHz: AT BE CH CY CZ DK FI BE CH CY DK HU IE IS FR GR HR HU IE IS IT IT MT NL NO SE SI LT MT NL PL SI TR 10.587GHz: GB only...
  • Página 2 All manuals and user guides at all-guides.com XDL15TT-AM PROGRAM OUTPUTS? IMPOSTA USCITE? Centrale? Endstation PGMs? ALARM N/O TAMPER ALARM N/C MASK/FAULT Usc. PGM [0000] [0000] Not Used Non Usato [0022] Usc. PGM [0022] Final Arm Any Ogni Area Inst. +12V 0V EOL INPUT 1 NO C NC PCX 46...
  • Página 3 All manuals and user guides at all-guides.com <10m >10m <24kg XD-FIXEDBRACKET XD-WALLBRACKET + XD-45D-ADAPTER XD-WALLBRACKET Powering Up Horizontal Coverage Masked/Blocked TOP PIR ALARM MICROWAVE Top PIR Failed Self Test <24kg Max: 15m Microwave Failed Self Test Bottom PIR Failed Self Test Vertical Coverage Low Voltage 1.3m...
  • Página 4: Technische Daten

    All manuals and user guides at all-guides.com Tier-immuner Außenbereichsmelder (15m) Huisdier-ongevoelige externe detector, 15 m Umweltklasse IV Milieuklasse IV 9,9 GHz: 10.525 GHz: 9,9 GHz: 10,525 GHz: AT BE CH CY CZ DK FI BE CH CY DK HU IE IS AT BE CH CY CZ DK FI BE CH CY DK HU IE IS FR GR HR HU IE IS IT...
  • Página 5 All manuals and user guides at all-guides.com Détecteur extérieur tolérant aux animaux domestiques, portée de 15m Rilevatore esterno 15 m con immunità agli animali domestici Detector externo inmune a las mascotas, 15 m Classe environnementale IV Classe ambientale IV Clase ambiental IV 9,9 GHz : 10,525 GHz : 9,9 GHz:...
  • Página 6: Garantia

    All manuals and user guides at all-guides.com Невосприимчивый к домашним животным внешний Detetor exterior imune a animais domésticos, de 15m Zewnętrzny czujnik 15 m nieczuły na zwierzęta domowe извещатель с диапазоном 15 м Classe ambiental IV Класс окружающей среды IV Klasa środowiskowa IV 9,9 ГГц: 10,525 ГГц:...