Intended Use - Pontec PondoDrain Mud 8000 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
Product Description
Overview
 A
Description
1
Handle, for lifting and carrying the pump
2
Stepped hose adapter, for connecting a hose with an inside diameter of 25 mm, 32 mm or 38 mm
3
Connection, pressure side, G1½
4
Pump base
5
Float switch, switches the pump on or off depending on the water level
6
Power connection cable

Intended use

Only use the product described in this manual as follows:
• For pumping clear water or rain water.
• Pumping of soiled water and particles up to the permissible grain size. (→ Technical data)
• For irrigating and watering.
• For transferring water from and draining basins or ponds/pools.
• Extraction of water from a well.
– Only for irrigation and watering purposes!
• For pumping the water out of water butts/rain barrels or cisterns.
• Operate the product in compliance with the technical data. (→ Technical data)
Possible incorrect use
The following restrictions apply to the unit:
• Not suitable for salt water.
• Not suitable for drinking water.
• Do not use for long-term operation (e.g. continuous recirculation of the water in a pond).
• Do not use for commercial or industrial purposes.
• Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
• Do not connect to the drinking water supply.
Installation and connection
Connecting the pressure hose
An optimum flow rate is achieved with a hose inside diameter of 38 mm (1½").
How to proceed:
 B
1. Adapt the stepped hose adapter to the hose diameter
2. Screw the stepped hose adapter onto the connection on the pressure side.
3. Connect the pressure hose to the stepped hose adapter.
– Secure the pressure hose with a hose clip.
Adjusting the float switch
When the water level rises, it lifts the float switch until the switch-on point is reached and the pump switches on.
When the water level drops, the float switch lowers until the switch-off point is reached and the pump switches off.
 C
• Push the float switch cable into the cable clip.
– The shorter the cable between the float switch and the cable clip, the lower the switch-on point and the higher the
switch-off point.
To ensure fault-free function, ensure that the cable length between the float switch and the cable bracket is at
least 100 mm.