Hydac FPU Serie Instrucciones De Servicio página 40

Dispositivo de llenado y control
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
2.2 FPU‑2 diagram
FPU‑2
Charging hose
Adapter A3H
Nitrogen supply
(pressure boost system)
Hydraulic accumulator (high pressure)
Fluid connection
EN
3.
Transport and storage
Transport
The FPU can be transported without special
precautions. Damage must be avoided.
NOTICE
A damaged FPU must never be put into
operation.
Storage
The FPU can be stored in any position.
The FPU must be kept in a cool, dry place,
protected from direct sunlight.
This can be in its packaging or in a protective
case (if included with delivery).
40
Pre-charge pressures
When working with the FPU, take into account
the influence of the charging temperature on
the pre‑charge pressure. For values, see fold‑
out page, Table 2 I.
T
The reference temperature is the temperature
for which HYDAC specifies/calculates the
corresponding reference pre‑charge pressure
(p
T [C°] = accumulator temperature
The accumulator temperature is the surface
temperature measured on the gas side of the
hydraulic accumulator.
p
The reference pre‑charge pressure is the pre‑
charge pressure of the hydraulic accumulator
at 20 °C. It is specified on the hydraulic
accumulator (label on the accumulator shell,
stamped on the accumulator shell, engraved
on the name plate) – see hydraulic accumulator
operating instructions.
NOTICE
Always comply with limits given in Overview
Brochure
"HYDAC Accumulator Technology"
No. 3.000
[C°] = reference temperature
0
); it is generally 20 °C (room temperature).
0
[bar] = reference pre-charge pressure
0

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fpu-1Fpu2

Tabla de contenido